Technogamma SineUPS Series User Manual Download Page 6

Troubleshooting

Problem

Solution

The device is connected to 
mains,   but   pressing   the 
button 

 does not turn it 

on.

The   device   does   not   function   without   a   connected  

battery!

 

If   you   are   using   a   car   battery,   please   check   the 

mounted terminals – some of them are painted on the 

inner side and do not ensure proper electrical contact to 

the battery contacts.

 

The battery should be in good condition. If the voltage 

of the connected battery is under 10.5V, then the device 
will not turn on /low voltage battery protection/.

The LED   does not 
indicate the presence of 
mains.

Check the device connections and mains voltage.
Check the device fuse and replace it if necessary.

The device makes long 
beep and turns itself of 
during power up.

Device internal error. Please contact the authorized 
service center.

The LED 

 is on and beeps 

every 30 sec.

Normal work in battery powered mode, the device is 
turned on and the mains is missing.

Inadequate work time in 
battery mode.

Check that the battery is fully charged (at least 10 hours).
With time the battery capacity decreases. Contact the 
authorized service for internal battery replacement 
(model 

S100a

) or replace the external battery with a new 

one (models 

S100

 and 

S200

).

6

Summary of Contents for SineUPS Series

Page 1: ...SineUPS Models S100a S100a S100 and S200 User manual...

Page 2: ...is powered by regular mains voltage it keeps the battery fully charged so it can provide its maximum capacity when needed Installation Warning SineUPS works at high voltage and requires special atten...

Page 3: ...talled battery there is possibility that some harmful gases can be released and in that case it is recommended to install the device in a proper location 3 Verify that the load and battery are properl...

Page 4: ...Battery 4 levels of battery charge each LED stands for 25 charge Mains power Stable mains The LED blinks if the mains voltage is not within the limits Error An error occurred overload overheat or inte...

Page 5: ...te on battery power depends on the capacity charge and condition of the connected battery as well as the power of the load connected When the battery charge goes below 10 the device beeps every 2 sec...

Page 6: ...protection The LED does not indicate the presence of mains Check the device connections and mains voltage Check the device fuse and replace it if necessary The device makes long beep and turns itself...

Page 7: ...W Voltage form Pure sine wave Switching time 5ms Protection Automatic resettable protection from overload and short circuit Battery Type 12V lead acid Capacity Internal 7 2 Ah Internal 7 2 Ah External...

Page 8: ...ing storms Usage in inappropriate conditions temperature and humidity Broken warranty stickers Warranty Card Sold client date ___________________________________________________ ______________________...

Reviews: