4 Technobake Pty 11/18 Hinkler Court, Brendale, Qld 07 3205 9055
Handle should self close from this
position.
Door
handle
in the
closed
position
– Should be vertical down.
Stop Bolt – this can be
adjusted to ensure handle is
vertical
11. Adjust so door is firm to
shut but not stressing the latch.
12. Check door safety switches on bottom of door are aligned correctly
and no more than 2mm gap between
sensors.
Must not be touching.
Check door switches by going to settings on
screen, Diagnostics, code 2906 enter.
Door switch, check value Top Close; Bottom Close
on both sides.
Open and close the door slowly to see the value
(numbers)move.
These values should be v when door is
shut.