Appendix C

Transmitter AG-105 Indication

Battery holder 

with  the handle in the 

center for removing. 

Contains 8 alkaline cells 

1,5V «type С».

Electrical power supply field

One of the three categories of 

power source VOLTAGE «U» and 

ABSORBED CURRENT «I» is always 

displayed by the glow of one of the 

three-coloured indicators.

Output parameters field

VOLTAGE «U, V», CURRENT «I, А» and load 

POWER «P,W» and also its RESISTANCE «R, 

 / k 

». 

 The only possible 

red 

glow of indicators of 

this field means «oscillation» is in progress. 

Internal parameters field

POWER SUPPLY VOLTAGE 

«

» and FREQUENCY of the 

generated continuous  «Co» or pulse 

«Pu» signals «

f, kHz

». 

Green

 glow of POWER SUPPLY 

VOLTAGE indicator 

«

» can be seen in the “stop” mode, 

red

 – in «oscillation» mode.

Internal induction transmitting 

antenna field «In»

In «antenna» mode «In» the orientation 

mark «In axis» should be positioned 

precisely above communication axis 
and oriented parallel to its direction.

CHOICE button

By sequenced presses MODE or 

PARAMETER indication can be chosen 

to be shown on the “Digital display”.

START/STOP button

The sequenced presses are switching 

the device from «STOP» mode to 

«OSCILLATION» and back.

Digital display

shows NUMERICAL value of the 

parameter («

 » / «f,кHz» / «U,V» 

/ «I,А» / «Р,W» / «R, 

 / k 

») and 

SYMBOLIC notation of the mode 

(«In» - internal transmitting inductor/ 

«An» - external induction transmitting 

antenna/ «Co» - continuous oscillation 

mode/ «Pu» - pulse modulation mode.

Type of the displaying value is defined 

by the CHOICE button. 

POWER 

button

on /off 

switching of 

the electric 

power 

supply

LESS/
MORE 

buttons

Decrement 

/ increment 

(adjustment) 

of the 

chosen 

(mode) or 

parameter 

value.

Modes field

has indicators of «ANTENNA»« » 

and «MODULATION» « 

» modes.

If “earrings” or “clamp” are 

connected to the output, the 

indicator « » not glowing.

In «Antenna» mode, the indicator 

« » is always glowing: 

green

 in 

case of internal antenna or 

yellow

 in 

case of external.

In case of «regular» (not modulated) 

signal the indicator «

» is not 

glowing.

In case of «MODULATION» (special 

form signal) the indicator 

«

» always glows: 

green

 in pulse 

mode «Pu».

Therefore, current operating mode 

is always displayed in the «modes 

field».

INDICATION EXAMPLES

«nominal» 

power supply 

voltage

«low» absorbed 

current

external 

antenna «An» is 

connected

pulse 

modulation 

mode «Pu»

«oscillation» 

operation mode

output voltage

 40V

«U» 

green

«I» 

green

« » 

yellow

«

» 

green

red

 glowing 

«

U,V

»

«

U,V

» → «40»

Summary of Contents for SUCCESS-438.15N

Page 1: ......

Page 2: ... depth detection of metal pipelines up to 6 m depth survey the ground before the ground works Broadband mode with frequency range between 0 05 and 2 0 kHz distance of tracing from the place of transmitter connection is up to 3 km indirect measurement of the depth Kit components are 1 Receiver АP 027 2 Electromagnetic sensorEMD 247 3 Headphones 4 Transmitter AG 105 4 3 1 2 Operation conditions Ambi...

Page 3: ...ocket 8 sensitivity buttons higher lower Technical specifications of the Receiver are listed in Appendix A Screen controls are listed in Appendix B Set of external PowerBank for example Xiaomi Mi Power Bank 20000 mAh with protective case and power adaptor питания SAMSUNG ART U90EWE 5 0 V 2 0 A 2 1 Preparing Receiver AP 027 for operation 1 Insert 4 AA elements in battery compartment of the receiver...

Page 4: ...cable and pipe locators 4 2 Set the receiver on the holder 3 Put one end of the holder below protective rubber of the receiver 4 Put other end of the holder below the second rubber 5 The receiver is ready for the operation It is recommended to adjust the length of the neck strap for more comfort during operation ...

Page 5: ...he receiver operability 2 1 To set the electromagnetic sensor from transport to operating position In order to do that loosen the locking nut 1 extend the bar 2 to a required length and fix with the locking nut 2 2 Loosen the locking nut 1 and install the electromagnetic sensor 2 in a position used in route detection Fix the position with the locking nut Horizontal position is used for route detec...

Page 6: ...nic component fHRM to another by buttons or 2 3 2 Conduct receiver setup For tracing of energized cables please set frequency 50 Hz 1 Switch on the measurement mode using the button 5 Set input signal level using sensitivity buttons and Level at the bottom of the scale must be within 50 90 of the maximum 2 To select the necessary frequency press the frequency button symbol will appear 3 Using butt...

Page 7: ...lar to the cable route In this case the maximum signal level is observed when the sensor antenna passes directly above the utility line The maximum method is intended for a quick route location Flat peaks of the signal level curve do not allow for high location accuracy but enables a quick route location 2 The Minimum method When the EMD antenna in a vertical transport position is placed directly ...

Page 8: ... hours with the use of standard fresh batteries e g Energizer C Using high capacity batteries for example Duracell ULTRA the duration of the autonomous operation can be extended by 20 30 If 12V external battery e g automotive is connected the operation time is defined by the battery capacity When connecting to the external power source of 15V the operating time is not limited The dimensions of the...

Page 9: ...receivers made by TECHNO AC The ingress protection rating of the casing is IP65 which completely precludes any ingress of the dust or water jets when lidded The operating temperature range is 30ºС to 60ºС with the external battery or mains supply 12 2 Control and indication elements See Appendix 3 12 2 1 Display functional fields of the front panel Electrical power supply field always displays rou...

Page 10: ...cording to the operator choice shows the following numerical values of the following parameters in the Digital field 1 POWER SUPPLY VOLTAGE in volts the lack of the glow another display parameter is chosen green colour glow power supply voltage in the stop mode red colour glow power supply voltage in the oscillation mode 2 FREQUENCY of the generated signal in kilohertz f kHz the lack of the glow a...

Page 11: ...whether oscillation process is running or stopped due to non use of the red colour the colour signifying the oscillation mode 12 2 5 Digital field at the discretion of the operator displays either numerical parameter value power supply voltage signal frequency f кHz output voltage U V load current I A load power Р W load resistance R Ω kΩ or symbolic notation of the mode In internal transmitting i...

Page 12: ...s earth return of the electric current in case of contact way of connection to the utility under examination with the use of output cable clips External battery cable is designed for connection to the battery as the external power supply source Clamp with red adhesive tape corresponds with the positive potential the clamp with black adhesive tape relates to the negative potential Transmitting indu...

Page 13: ...rease until the moment when the values of the absorbed current and load current will not exceed the figures set by the program If pre set load current value is not achieved due to the high load resistance then maximum possible output voltage is defined Upon completion or interruption by START STOP buttons of the automatic adjustment process the manual control over the voltage current power is avai...

Page 14: ...s at the initial power of 5W 12 6 Illustrative use information about Power supply monitoring Buttons functionality Symbols Ontheinnersideofthecoveronecanseeinformationontheprincipleofthefollowinginformation types representation namely POWER SUPPLY MONITORING BUTTONS FUNCTIONALITY AND SYMBOLS of the Digital field and the front side of the panel 12 7 Multimeter of the output parameters In the Digita...

Page 15: ...ts of the thee falling notes during manual shutdown of the device by the pressing POWER button 13 Working with the device Prior to the contact connection it is necessary to make sure that the utility under examination has no voltage to earth and also that there are no works carried out or scheduled to be conducted which execution can lead to deliberate or accidental contact with conductive part wh...

Page 16: ...to the input of the utility under examination and the second one to the earth rod or to the relevant earthing e g standard earthing bus at maximum distance from the utility It is essential to provide close contact with utility and earth The opposite end of the utility under examination should be earthed for creating the paths for earth return of the signal revocable current Special option bare PIP...

Page 17: ...should be earthed for creating a path for earth current return of the signal 3 If the external induction transmitting antenna is in use An then it should be located as close as possible to the examined utility and coplanar with it The utility locator shouldn t be used nearby the transmitting antenna in order to avoid the immediate induction connection apart from the utility If the utility is not a...

Page 18: ...en in the Digital field by LESS MORE buttons for loads clips or clamp 512Hz 0 5 1024Hz 1 0 8192Hz 8 2 32768Hz 33 for antenna modes In or An 8192Hz 8 2 32768Hz 33 The generation frequency is set if possible lower but according to recommendations of the chosen utility locating method and proceed from the premise that the lower the frequency the less re inducing to the nearby facilities the less the ...

Page 19: ... antenna IEM 301 5 allow to provide the higher emission intensity and more convenient access immediately to the utility in comparison to the use of internal transmitting antenna In 12 5 2 If the external induction transmitting antenna is connected to the OUTPUT connector the device is in ANTENNA mode АН yellow and in the Digital field when choosing symbol An is indicated 12 5 3 For maximum inducin...

Page 20: ...mp is inversely related to the signal frequency at its constant voltage 12 6 3 If the identification of the chosen utility in the bunch is required it is necessary to earth all output ends of the bunch 12 6 4 Then the chosen utility should be wrapped around with a clamp 12 6 5 The press of the START STOP button is initiating the automatic adjustment Upon the completion or interruption by pressing ...

Page 21: ...id their possible useless charge consumption 13 8 Electromagnetic compatibility The present device is subsumed under information technology equipment ITE class A according to Russian Stage Standard GOST 51318 22 2006 Such equipment should not have any sale restrictions When used in private households this equipment could disturb the smooth running of other technical equipment because of the indust...

Page 22: ... kHz Gain factor 100 dB Visual indication Liquid crystal display symbols and meaning of the chosen modes and parameters animated moving scale of the output signal level digital value and animated moving scale of the output signal level graphic moving diagram of the output signal level frequency content of the output signal level digital and graphic display of output signal levels kept in the memor...

Page 23: ...de 2F 40 in other modes Maximum output power W Restricted by the program 20 In the continuous Co and pulse Pu modes at frequencies 512Hz 0 5 1024Hz 1 0 8192Hz 8 2 at load resistance up to 80Ω In dual frequency mode 2F at load resistance up to 50Ω 6 At frequency 32768Hz 33 at load resistance up to 260Ω Power supply sources Operating range of the supply voltages Minimally acceptable voltage for osci...

Page 24: ...via buttons LESS MORE after the automatic adjustment Connection options to the utility under examination Contact connection with earth return Non contact connection with application of the internal transmitting antenna In Non contact connection with the use of external induction transmitting antenna An the emission intensity is higher and easier access to the utility in comparison with the interna...

Page 25: ...rged battery and the device will automatically switch off after type of the sensor connected Sensor not connected Acoustic sensor AD Electromagnetic sensor EMD type of signal received when working with AD sound of liquid leakage continuous acoustic signal sound generated by an impact acoustic impulses during transmitter operation During work with electromagnetic sensor continuous signal from the p...

Page 26: ...nifies output overload Filtering Displays the frequency range scales with numerical and graphical representation of the pass band During work with AD pass band filter broadband DuringworkwithEMD central frequency of the narrow band filter broadband Presence of the indicator signifies possibility of filter parameter adjustment The filter is switched on and off by using the filter button Scale Conta...

Page 27: ...ue of the signal in the mode current value of the signal in the mode and maximum current value of the signal for the previous second pulse amplitude 5 Acoustic signal spectrum window It displays the spectrum of the filtered signal When working with EMD switching the window can have the following view Fig А 4 Fig А 5 dark segments correspond to the frequency components of valid continuous signal li...

Page 28: ... be called for by pressing the button The display shows the industrial frequency spectrum of 0 40 8 60 kHz Two segment columns display the current and minimum values of the frequency components of the signal 8 Memory window Fig А 6 Fig А 7 value of the valid signal level Number of memory cells Selection of memory cells is performed by buttons levels of useful signal fixed by memory buttons pressin...

Page 29: ...ural sound is used When working with EMD in the mode natural sound to the phones the adopted high active frequency 8192Hz and 33kHz before playing are converted into a well acceptable low frequencies of 1575 Hz and 3470 Hz respectively Synthesized sound is created by a principle Frequency of the audible sound signal pitch is directly proportional to the signal level and the volume does not depend ...

Page 30: ... can be chosen to be shown on the Digital display START STOP button The sequenced presses are switching the device from STOP mode to OSCILLATION and back Digital display shows NUMERICAL value of the parameter f кHz U V I А Р W R Ω k Ω and SYMBOLIC notation of the mode In internal transmitting inductor An external induction transmitting antenna Co continuous oscillation mode Pu pulse modulation mod...

Reviews: