1.
Turn the nut (A) of the connector clockwise
using the quick-fix spanner
2.
Continue to turn it up to the nut will not turn
more. You will hear a noise due to
friction of the key on the nut
3.
At this point you have the nut tighten with a
torque force of 2.0 Nm
÷ 2.5 Nm
4.
Important: the cable gland (B) will be
tightened automatically when turning the
nut (A)
5.
Cable retention and IP68 resistance are
guaranteed (acc. to EN61984 and
EN60998/EN60529)
How to use the quick-fix spanner (cont.)
© Techno Srl All rights reserved.
example
9
A
B