5.1 Task:  

Indirect electromagnetic mode of depth 

measuring 

Equipment used:  

receiver AP-027, electromagnetic 

sensor EMD

Tip:  When  determining  the  depth,  one  should  take  into 

account the terrain. In order to obtain precise results, select 
flat surface areas.

Method: 

1. Find the precise pipeline route location 

(preferably using the minimum method). Mark the spot.
2.  Fix the sensor antenna at a 45 angle to the ground surface,

minimum of the signal is observed at a distance from the point 
«above the route», equal to the depth of the utilities, when the 
antenna axis intersects the axis of the route. This is the indirect 
method of measuring the depth of utility (

fig. 5.1

)

5.2  Task:  Detecting the pipeline and utility lines intersection point. 
Equipment used: 

receiver AP-027, electromagnetic 

sensor EMD, headphones. 

Fig.5.1

Fig.5.2

Method: 

1. Perform preliminary pipeline route location.

2. Turn on the receiver and set it up for broadband.
3. Рosition the electromagnetic antenna over the

pipeline, parallel to the pipeline route (signal level 
displayed on the receiver screen will be close to zero)
(

fig. 5.2

). Perform route location in accordance with 

the maximum method. When following the route, the 
intersection points with utility lines can be identified by 
the maximum signal.

Summary of Contents for SUCCESS CBI-436N

Page 1: ......

Page 2: ...nd up to 6 m depth Survey the ground before the ground works Broadband mode with frequency range between 0 05 and 8 6 kHz Indirect measurement of the depth Kit components are 1 Electromagnetic sensor...

Page 3: ...s of the Receiver are listed in Appendix A Screen controls are listed in Appendix B Set of external PowerBank for example Xiaomi Mi Power Bank 20000 mAh with protective case and power adaptor SAMSUNG...

Page 4: ...end of the holder below protective rubber of the receiver 4 Put other end of the holder below the second rubber 5 The receiver is ready for the operation It is recommended to adjust the length of the...

Page 5: ...ansport to operating position In order to do that loosen the locking nut 1 extend the bar 2 to a required length and fix with the locking nut 2 2 Loosen the locking nut 1 and install the electromagnet...

Page 6: ...tup For tracing of energized cables please set frequency 50 Hz 1 Switch on the measurement mode using the button 5 Set input signal level using sensitivity buttons and Level at the bottom of the scale...

Page 7: ...rved when the sensor antenna passes directly above the utility line The maximum method is intended for a quick route location Flat peaks of the signal level curve do not allow for high location accura...

Page 8: ...of the utilities when the antenna axis intersects the axis of the route This is the indirect method of measuring the depth of utility fig 5 1 5 2 Task Detecting the pipeline and utility lines intersec...

Page 9: ...l value and animated moving scale of the output signal level graphic moving diagram of the output signal level frequency content of the output signal level digital and graphic display of output signal...

Page 10: ...of the sensor connected Sensor not connected Acoustic sensor AD Electromagnetic sensor EMD type of signal received when working with AD sound of liquid leakage continuous acoustic signal sound generat...

Page 11: ...numerical and graphical representation of the pass band During work with AD pass band filter broadband DuringworkwithEMD central frequency of the narrow band filter broadband Presence of the indicator...

Page 12: ...e and maximum current value of the signal for the previous second pulse amplitude 5 Acoustic signal spectrum window It displays the spectrum of the filtered signal When working with EMD switching the...

Page 13: ...trial frequency spectrum of 0 40 8 60 kHz Two segment columns display the current and minimum values of the frequency components of the signal 8 Memory window Fig 6 Fig 7 value of the valid signal lev...

Page 14: ...the phones the adopted high active frequency 8192Hz and 33kHz before playing are converted into a well acceptable low frequencies of 1575 Hz and 3470 Hz respectively Synthesized sound is created by a...

Reviews: