![Technisonic Industries Limited ACCESS/A A710X Installation And Operating Instructions Manual Download Page 12](http://html1.mh-extra.com/html/technisonic-industries-limited/access-a-a710x/access-a-a710x_installation-and-operating-instructions-manual_1069741012.webp)
ACCESS/A A710X / A711X Installation & Operating Instructions
06RE387 rev. B
Technisonic Industries ltd. Copyright 2007 BY TiL ALL RIGHTS RESERVED
Page 1-7
1.6 SYSTEM
LIMITATIONS
A summary of the relevant system limitations is given below.
Induced Signal Susceptibility, RF Susceptibility and RF Emission
The wiring connections called out in the Installation and Operating Instructions, chapter 2,
describes shield terminations for minimum ground loop noise. The test harnesses used for
RTCA/DO-160 sections 19, 20, and 21 – Induced Signal Susceptibility, RF Susceptibility, and
Emission of RF Energy respectively - used shield terminations at both ends of the cable. Should
RF susceptibility pose a problem in a particular installation the installer may wish to try
terminating shields at both ends of the cable, further, if this does not produce satisfactory results
then double shielding may be required.