FL
error
code
display
Symptom
Probable cause
Signal to check
Normal voltage and
waveform values
Signal
name
Location
PLAY
STOP
E01
Focus and
tracking
offset
adjustments
not
completed in
the specified
time period.
Clocks X1 IN and X2 OUT,
power supply VDD and reset/
RST, all on IC702.
MDATA, MCLK and MLD
signals to/from IC201.
MDATA IC702-pin 8
0 V
MCLK IC702-pin 7
3.3 V
MLD
IC702-pin 9
3.3 V
/RST
IC702-pin
18
3.3 V
3.3 V
X1 IN
IC702-pin
58
X2 OUT IC702-pin
59
E02,
E04,
E06,
E0A,
E0C,
E0E
Disc play
unstable.
Scratches or contaminants on
disc surface.
Focus and Tracking servo
circuits. (check waveforms,
voltages and part values.)
Spindle driver circuit.
Optical pickup.
FE
IC702-pin
32
1.7 V
TE
IC702-pin
33
1.7 V
FOD
IC702-pin
28
1.7 V
1.7 V
TRD
IC702-pin
27
1.7 V
1.7 V
/RFDET IC702-pin
38
0 V
3.3 V
RF
TJ701
1.0 V
STAT
IC702-pin
17
3.3 V
0 V
FBAL
IC702-pin
30
1.7 V
1.7 V
Summary of Contents for SL-HD550
Page 8: ...Check the main P C B as shown below...
Page 9: ...6 2 Checking for the CD servo P C B Follow the Step 1 Step 3 of item 6 1...
Page 10: ......
Page 11: ...Check the CD servo P C B as shown below...
Page 13: ......
Page 14: ......
Page 15: ......
Page 16: ......
Page 17: ......
Page 18: ......
Page 19: ......
Page 20: ......
Page 21: ......
Page 22: ......
Page 23: ......
Page 24: ......
Page 25: ......
Page 27: ......
Page 28: ......
Page 46: ......
Page 47: ......
Page 53: ...Forced mode...