file:///C|/Documents%20and%20Settings/Administrator/Plocha/SL-EH570/s0601020000.htm
6.1.2 Checking the mechanism switches
TOP
PREVIOUS
NEXT
1. After a servo section error code is displayed, press the F.SKIP button.
2. A mechanism OK/NG error code is displayed. Refer to Table 6-1. This error code can be used
diagnose whether the mechanism is OK or not. If there are multiple errors, these can be displayed
successively by pressing the F.SKIP button.
3. Press the STOP button, then remove the disc and turn off the power. (The error code display mode
is canceled.)
Table 6-1.
FL display
Symptom
Cause
H15
When CD tray opens, it closes by itself.
Tray open detect switch (S790) fault.
H16
When CD tray closes, it opens by itself.
Tray close detect switch (S791) fault.
F15
Does not play even if the PLAY button is pressed.
Pickup rest position detect switch (S701) fault.
F26
Disc not move even if the PLAY button is pressed. System control and servo processor IC (IC451, IC702) fault.
•@
TOP
PREVIOUS
NEXT
file:///C|/Documents%20and%20Settings/Administrator/Plocha/SL-EH570/s0601020000.htm [25.4.2003 20:56:27]