2

Technical Manual LDK 4628 - Operational Control Panel

02.33.2

Safety Summary

This informaton is intended as a guide for trained and
qualified personnel who are aware of the dangers involved
in handling potentially hazardous electrical/electronic
equipment. It is not intended to contain a complete list of
all safety precautions which should be observed by
personnel in using this or other electronic equipment.

The installation, maintenance and service of this equipment
involves risks both to personnel and equipment and must
be performed only by qualified personnel exercising due
care.

Personnel engaged in the installation, operation,
maintenance or servicing of this equipment are urged to
become familiar with First Aid theory and practises.

During installation and operation of this equipment, local
building safety and fire protection standards must be
observed.

Before connecting the equipment to the power supply of
the installation, the proper functioning of the protective
earth lead of the installation needs to be verified.

Whenever it is likely that safe operation is impaired, the
apparatus must be made inoperative and secured against
any unintended operation. The appropriate servicing
authority must then be informed. For example, safety is
likely to be impaired if the apparatus fails to perform the
intended function or shows visible damage.

This product has been designed and tested according to
EN60065.

Cautions and Warnings

When performing service, be sure to read and comply with
the warning and caution notices appearing in the manuals.
Warnings indicate danger that requires correct procedures
or practices to prevent death or injury to personnel. Cautions
indicate procedures or practices that should be followed
to prevent damage or destruction to equipment or property.

WARNING

THE CURRENT AND VOLTAGES PRESENT IN THIS

EQUIPMENT ARE DANGEROUS. ALL PERSONNEL

MUST AT ALL TIMES FOLLOW THE SAFETY

REGULATIONS.

ALWAYS DISCONNECT POWER BEFORE REMOVING

COVERS OR PANELS.

ALWAYS DISCHARGE HIGH VOLTAGE POINTS

BEFORE SERVICING.

NEVER MAKE INTERNAL ADJUSTMENTS, PERFORM

MAINTENANCE OR SERVICE WHEN ALONE OR WHEN

FATIGUED.

IN CASE OF AN EMERGENCY ENSURE THAT THE

POWER IS DISCONNECTED.

ANY INTERRUPTION OF THE PROTECTION

CONDUCTOR INSIDE OR OUTSIDE THE APPARATUS,

OR DISCONNECTION OF THE PROTECTIVE EARTH

TERMINAL, IS LIKELY TO MAKE THE APPARATUS

DANGEROUS. INTENTIONAL INTERRUPTION IS

PROHIBITED.

FOR SAFETY REASONS THE CPU MUST BE MOUNTED

IN A 19-inch RACK WHICH HAS SAFETY COVERS

ACCORDING TO IEC65.

WHEN TWO CPUs ARE MOUNTED ABOVE EACH

OTHER THE MINIMUM DISTANCE BETWEEN THEM

MUST BE 50MM OR THE RACK MUST BE FORCE-AIR

COOLED.

USE ONLY FUSES OF THE TYPE AND RATING

SPECIFIED.

CAUTION

To prevent risk of overheating, ventilate the product

correctly.

Connect the product only to a power source with the

specified voltage rating.

Only connect a Triax cable from the LDK 6 camera

family to an LDK 6 CPU. Never connect it to any other

base station.

Never connect the Triax cable from a camera to a

CPU of a different family; never connect the LDK

family to the TTV family.

Do not allow system ground currents to exceed 1.5A

in the outer shield of the triax cable or 0.2A in other

cable shields.

It is strickly prohibited to short circuit the inner and

outer shields of a triax cable used to connect a

camera to a base station.

Summary of Contents for LDK 4628/01

Page 1: ... Standard Store On air Auto iris F Number Extender Cam select 4 1 15 8 Iris Free Call Preview Centre Range Series 9000 OCP Cam pwr Pan lock OCP pwr Camera Base St Gen lock Triax Non standard Exposure Gamma Monitoring 1 2 Var Lin Variable R G B Sup CVBS Seq Saturation Wh clip Blk str Blk str Saw Gamma Flare Contour Var V level Level Lev dep Var Bars Contour Auto Auto wh Auto blk Point Slope Knee Pr...

Page 2: ...modification au cours de l évolution technique Thomson Multimedia Broadcast Solutions 2002 We Thomson Broadcast Solutions Nederland B V Kapittelweg 10 4827 HG Breda The Netherlands declare under our sole responsibility that this product is in compliance with the following standards EN60065 EN55103 1 EN55103 2 following the provisions of a the Safety Directives 73 23 EEC and 93 68 EEC b the EMC Dir...

Page 3: ... Contents Safety Summary 2 Cautions and Warnings 2 Earthing 3 Packing Unpacking 4 Opening the Operational Control Panel 5 Mounting in a Desk 6 Mounting in a 19 inch Rack 8 Internally Selectable Functions 10 Replacing the fuses 11 Interconnections 12 Two wire Data Control Bus 14 Connectors and Cables 15 Dimensions 17 ...

Page 4: ...ings indicate danger that requires correct procedures orpracticestopreventdeathorinjurytopersonnel Cautions indicate procedures or practices that should be followed to prevent damage or destruction to equipment or property WARNING THE CURRENT AND VOLTAGES PRESENT IN THIS EQUIPMENT ARE DANGEROUS ALL PERSONNEL MUST AT ALL TIMES FOLLOW THE SAFETY REGULATIONS ALWAYS DISCONNECT POWER BEFORE REMOVING CO...

Page 5: ...y a metal strap The protective earth terminal is internally connected to the protective earth conductor of the power cable If required the central earth connection wire of the studio can be connected to terminal PE In normal circumstances the connection between the protective earth and the video earth should not be broken The metal strap may be removed only if the studio or OB van is equipped with...

Page 6: ...g returned to Thomson Multimedia Broadcast Solutions for servicing try to use the containers and materials of the original packaging Attach a tag indicating the type of service required returnaddress modelnumber fullserialnumberand the return number which will be supplied by your Thomson Multimedia Broadcast Solutions service centre If the original packing can no longer be used the following gener...

Page 7: ...02 33 2 Technical Manual LDK 4628 Operational Control Panel 5 Opening the Operational Control Panel ...

Page 8: ...Flare Contour Var V level Level Lev dep Var Bars Contour Auto Auto wh Auto blk Point Slope Knee 1 Clr 2 3 4 5 6 7 8 Cap Aw 1 Aw 2 7500 K 5600 K 3200 K 0 Gain Black Scene file 1 2 3 Standard Store On air Auto iris F Number Extender Cam select 4 1 15 M black Iris 8 Free Call Preview Centre Range Col Temp Gain Filter Hole in desk required 350 7 mm x 106 3 mm 1 Remove upper panel by loosening screws a...

Page 9: ...our Auto Auto wh Auto blk Point Slope Knee 1 Clr 2 3 4 5 6 7 8 Cap Aw 1 Aw 2 7500 K 5600 K 3200 K 0 Gain Black Scene file 1 2 3 Standard Store On air Auto iris F Number Extender Cam select 4 1 15 M black Iris 8 Free Call Preview Centre Range Col Temp Gain Filter 350 7 5 Mounting Plates 3 Usetwoscrewstoattachthemountingplatestothe sides of the hole If desk height is less than 20 mm use two angled p...

Page 10: ...evel Level Lev dep Var Bars Contour Auto Auto wh Auto blk Point Slope Knee 1 Clr 2 3 4 5 6 7 8 Cap Aw 1 Aw 2 7500 K 5600 K 3200 K 0 Gain Black Scene file 1 2 3 Standard Store On air Auto iris F Number Extender Cam select 4 1 15 M black Iris 8 Free Call Preview Centre Range Col Temp Gain Filter Mounting Plate Mounting Plate Mounting in a 19 inch Rack 1 Remove upper panel by loosening screws and dis...

Page 11: ...dep Var Bars Contour Auto Auto wh Auto blk Point Slope Knee 1 Clr 2 3 4 5 6 7 8 Cap Aw 1 Aw 2 7500 K 5600 K 3200 K 0 Gain Black Scene file 1 2 3 Standard Store On air Auto iris F Number Extender Cam select 4 1 15 M black Iris 8 Free Call Preview Centre Range Col Temp Gain Filter 19 module rail with mounting strip 19 module rail with mounting strip 3 Use four screws to mount operational control int...

Page 12: ... Data Subboard This jumper S1 has two positions AB WatchdogOn AC Watchdog Off The Data Subboard is normally delivered with the jumper S1 in position AB Watchdog On User Jumpers With Jumper S4 you can choose between Complete Panel Lock or beneath Gain Field no Panel Lock This Jumper S4 has two positions AB Complete Panel Lock AC Beneath Gain Field no Panel Lock The Data Board is normally delivered ...

Page 13: ...02 33 2 Technical Manual LDK 4628 Operational Control Panel 11 Replacing the fuses ...

Page 14: ...400 m 7 875 ft with 14 mm cable Base Station LDK 4501 LDK 200 Triax Cable Maximum Length 2 400 m 7 875 ft with 14 mm cable LDK 23HS mkII with LDK 4482 SuperXPander CABLE TEST AC DC CAM ON ON AIR 0 mains Camera Processing Unit HS mkII Triax Cable Maximum Length 800 m 2 625 ft with 14 mm cable 1000 m 3281 ft with minor performance degradation Base Station LDK 4501 CPU LDK 4058 mkII Clear ND1 4 ND1 1...

Page 15: ...d camera systems in one chain can be handeld however inamultiplesystemtheloadofaLDK 23 HS mkII is twice the load of a standard camera This configuration is the multiple camera Triax mode The camera is connected to a CPU as in the single camera Triax mode The data bus is looped through from CPU to CPU s Base Stations OCP s and MCP The OCP s Operational Control Panels are used to controlthecamerasan...

Page 16: ...y on the units during installation Theassignmentnumberofacameraheadconnected to a Base station is automatically set to the number of the Base station to which it is connected The number on the Base station which is connected to the data bus mustbesettothenumberoftheassignedcontrol panel It is important to set a unique number for each Base station OCPgroupasunpredictablecontrolsituations could aris...

Page 17: ...ector Panel Mains Input Connector Eurostyle 3 pin male 1 Neutral 2 Line 3 Earth Mains input voltage Between 230 Vac and 115 Vac 15 Mains frequency 47 to 63 Hz Fuses 1 A slow 250 Vac X 1 Mains Input Connector Panel view Rear view of OCP X 891 X 890 X 897 X 878 not used Mains input connector X 1 3 2 1 ...

Page 18: ...el view Data Connectors 9 pin male shielded cable 1 Preview 1A 2 Preview 1B 3 Preview 1C 4 Not used 5 Not used 6 Not used 7 Not used 8 Not used 9 Shield Shield of cable directly to the pin marked shield A 9 pin female cable connector is available under part number 2422 022 06216 The cable hood for this connector is available under part number 2422 021 02467 Preview switch not pressed 1A connected ...

Page 19: ...ring Variable Saturation Wh clip Blk str Blk str Saw Gamma Flare Contour Var V level Level Lev dep Var Bars Contour Auto Auto wh Auto blk Point Slope Knee 1 Clr 2 3 4 5 6 7 8 Cap Aw 1 Aw 2 7500 K 5600 K 3200 K 0 Gain Black Scene file 1 2 3 Standard Store On air Auto iris F Number Extender Cam select 4 1 15 M black Iris 8 Free Call Preview Centre Range Col Temp Gain Filter 100 00 mm 40 00 mm 58 94 ...