Find us on the web. www.tecsol.com.au
P:\IR-Relay\Construction-Air-Cond\Docs-pics\AC-Ultra-aircon-ECU-
INTERFACE.doc
Setting up the ClickToPhone HouseMate with Prog codes to control the Air
Conditioner Interface
•
With Click2phone version 77 on you can load the pre-formatted Air conditioner
page with IR code set into HouseMate.
o
Create a new Housemate page > Long press on vacant cell and choose
Open another grid
o
On the new grid, Menu > Signals > TSA Air Con > Menu > Wizard > OK
o
The Air Conditioner Interface should respond to these buttons ‘out of the
box’ but if not, you can follow the procedure below to record the new Prog
codes into your Air Conditioner Interface
•
Otherwise you can create a HouseMate page with 4 new buttons and load them
with any 4 PROG Codes – From the new HouseMate page press
Menu/Signals/Gewa Codes
o
Then follow the procedure below to record the new Prog codes into your
Air Conditioner Interface
Recording new Prog codes into the Air Conditioner Interface
The Air Conditioner Interface can learn Prog Infra Red codes for each function, and
store them in permanent memory. If the factory default codes listed above are not
suitable you can follow this procedure to make the unit respond to different signals.
1.
Choose the PROG level and the four keys that you want to
use. Make sure these keys have been reset to the default
code, as explained above.
2.
Choose an area away from direct light to avoid interference to
the learning process.
3.
Plug the Air Conditioner Interface to the power in the normal
way, and using a pen,
press and hold
the recessed button on
the back of the unit corresponding to the key you want to
reprogram. (Sometimes it’s easier to do this with two people!)
4.
Place the Prog at a distance of about 20cm and point it
towards the front of the interface, press the button on the
Prog you want to associate with the air conditioner function for about 2
seconds.
5.
Repeat the process for the remaining buttons.
You can retrain or change the codes as many times as you want. The Air Conditioner
Interface stores the codes in permanent memory, and will not loose the settings if
power is removed.
OPTIONAL: Setting the “Relay Off Delay”
The “Relay off Delay” is the length of time that the relay will stay
operated after the IR signal ends.
The “Relay off Delay” can be set any where between 1 & 20 seconds.
1.
Turn OFF the power to the IR Relay unit
2.
Press and hold press the button you wish to adjust
3.
Turn ON the power to the IR Relay unit
4.
Release
button
after
your
desired
time
(1 to 20 sec)
5.
Repeat steps 1-4 for each relay for which you wish to set the delay
Eg. If you hold the button pressed for 5 seconds the relay will release 5 seconds after
the IR signal stops.