The set IP-address is part of the PLP header if PLP is activated.
2.2.1.2
Rotary-Switch in status E
The IP address 10.104.3.110 is the default IP-address. In this Rotary-Switch status the
IP-address is configurable on the System Information tab. The configured IP-address
is valid even there is a power reset, or the Rotary-Switch has been changed and is
switched back to “E”. The valid IP
-address in this Rotary-Switch position is part of the
PLP header if PLP is activated.
2.2.1.3
Rotary-Switch in status F
The IP address 10.104.3.111 is the default IP-address. It is not configurable. The IP-
address is not overtaken after changing the rotary switch from any position to position
“F”. There will be no software reset. A power reset is needed. But if there is a p
ower
reset in this Rotary-Switch status, the CM_100_High will be reset to out of the box
status.
Complete
configuration will be lost and set to default.
To get access again by another IP-address, once a power reset is needed in another
Rotary Switch positi
on than “F”.
2.2.2
Status LEDs
The
CM_100_High
has several status LEDs at the front side of the case.
Figure 2-6: LED allotment on front of the device
Left side (
1
):
LED 1:
The “100BT1” shows the linkup on
the 100BASE-T1-Port to the microcontroller
LED 2:
Th
e “FPGA” LED
toggles (approx. 2 sec) during normal operation. If it is not
blinking or blinking faster, FPGA is damaged and must be repaired
LED 3:
The “Host” LED can toggle at
two different speeds:
o
Slow toggle (approx. 1 sec) during normal operation
o
Fast toggle (approx. 0.2 sec) if device is in Bootloader mode