background image

 

 
 

100BASE-T1 MediaConverter NXP 

User Manual

  

1.1.2

 

Technical data 

 

Voltage requirement: 

8 to 16 Volt DC (nominal 12 Volt DC) 

Power consumption: 

2 Watt 

Size: 

92 x 63 x 30 mm 

Weight: 

0,2 kg 

International Protection: 

IP 2 0 

Operating temperature: 

-40° to +80 °Celsius 

 

1.1.3

 

Links 

The User can download the latest firmware and documentation for the 100BASE-T1 
MediaConvert_NXP 

here

: 

 

1.1.4

 

General operating and safety strategy of TE Products 

 

Technica Engineering’s products are designed for operation  in  automotive systems 

and for supply voltages of nominal 12 V or 24 V. The applicable limit, values adhere to 
the  standard  norms  for  12  V  or  24  V  automotive  onboard  power  systems 
correspondingly and can be found in the mentioned norms. 
 

Should Technica Engineering’s products be operated in voltage ranges beyond 

those 

specified in the norms, which represents a breach of the conditions of operation, then 
this will void the product warranty and Technica Engineering will assume no liability 
whatsoever for the results and/or consequences thereof.  
 
This is especially valid whenever the voltage level reaches or exceeds the limits of the 
low-voltage directive. In this case, damage to the devices cannot be excluded. Due to 
the manufacturing characteristics of the devices, there is no imminent fire hazard from 
the device itself, if the devices are being operated in an environment according to the 
conditions  of  use.  A  secondary  fire  hazard  cannot  be  excluded,  should  those 
conditions not be met. Protection against overvoltage cannot be provided in such a 
breach of the conditions of use. 
 

1.1.5

 

General design rules for the power supply of TE 
products 

 

The power supply solution of Technica Engineering’s products is equipped with a self

-

protection  mechanism.  This  automatic  function  protects  the  internal  electronic 
components against excessive temperature and too high supply-voltage by switching 
the  device  off.  This  automatic  switch-off  function  is  independent  of  any  software 
function. Excessive temperatures in the device, can be caused by high environmental 

Summary of Contents for 100BASE-T1 MediaConverter NXP

Page 1: ...100BASE T1 MEDIACONVERTER NXP Manual Version 2 5 Hardware Version 1 5 USER MANUAL July 2020...

Page 2: ...E products 4 1 2 Warranty and safety information 5 1 3 RoHS certificate of compliance 7 1 4 Scope of delivery 7 2 Hardware interfaces 8 2 1 Connectors 8 2 1 1 Black MQS connector 1 8 2 1 2 RJ 45 ether...

Page 3: ...XP transmits data frames directly from the physical layer BroadR Reach 100BASE T1 to Fast Ethernet 100BASE TX with a constant delay time of 2 0 s 1 1 1 Features 1 port BroadR Reach 100BASE T1 Ethernet...

Page 4: ...nty and Technica Engineering will assume no liability whatsoever for the results and or consequences thereof This is especially valid whenever the voltage level reaches or exceeds the limits of the lo...

Page 5: ...ice read this manual thoroughly and retain it for your reference The latest documentation for the 100BASE T1 Media Converter NXP can be downloaded here As a user of this device you may only perform ta...

Page 6: ...en using safety critical systems and must be included in the safety assessment when used The development class in a safety system must be taken into account with standard QM referred to ISO26262 The d...

Page 7: ...gineering s 100BASE T1 MediaConverter NXP complies with RoHS Restriction of Hazardous Substances Directive Certificate of Compliance 1 4 Scope of delivery The delivery includes 1x 100BASE T1 MediaConv...

Page 8: ...the 100BASE T1 MediaConverter_NXP Figure 2 1 100BASE T1 MediaConverter_NXP 2 1 1 Black MQS connector 1 The pinning of the ECU connectors is listed on the label on top of the device as well See FIGURE...

Page 9: ...f black MQS connector You can use the official Tyco tool for these crimp contacts A cheap variant is the crimp tool for PSK contacts Pin Function Pin Function 1 Battery 12 Volt Input 10 Power Ground 2...

Page 10: ...he case for the 100BASE T1 Port color Description Green It is lit when there is a linkup on the 100BASE T1 port Yellow It is toggling in alternation with the green LED when there is communication Tabl...

Page 11: ...s set to Master 100BASE T1 Port is set to Slave 2 ON up OFF down 100BASE T1 Port is set to FullOut 100BASE T1 Port is set to HalfOut Table 4 Configuration of DIP Switches In a 100BASE T1 Link one devi...

Page 12: ...a standard use case of the 100BASE T1 MediaConverter_NXP Figure 4 1 Example of a use case MC MediaConverter DUT Device under Test DIP Switch 2 should be always ON DIP Switch 1 is dependent on the DUT...

Page 13: ...Converter NXP User Manual 13 5 100BASE T1 filter The following 100BASE T1 filter is used in the 100BASE T1 MediaConverter_NXP Hardware version 1 0 and following Figure 5 1 100BASE T1 filter for HW v1...

Page 14: ...segments is limited to 15 meters The difference between the 100BASE T1 MediaConverter_BCM and 100BASE T1 MediaConverter_NXP is the used transceiver for the 100BASE T1 PHY At the beginning of developm...

Page 15: ...rter NXP User Manual 15 7 List of figures Figure 1 1 100BASE T1 MediaConverter_NXP 3 Figure 2 2 100BASE T1 MediaConverter_NXP 8 Figure 4 1 Example of a use case 12 Figure 5 1 100BASE T1 filter for HW...

Page 16: ...1 2 Extension of warranty and safety 23 03 2020 2 3 All Optical adaption 23 03 2020 2 4 All Small spelling corrections May 2020 2 5 1 1 4 Added information on General Operating and Safety Strategy of...

Page 17: ...this product please feel free to contact us Technica Engineering GmbH Leopoldstr 236 80807 M nchen Germany Technical support support technica engineering de General information Info technica engineer...

Page 18: ...isel internetiaadressil https technica engineering de wp content uploads 2021 03 eu declaration of conformity 1600 pdf English Hereby Technica Engineering GmbH declares that the product 100BASE T1 Med...

Page 19: ...ca engineering de wp content uploads 2021 03 eu declaration of conformity 1600 pdf Nederlands Hierbij verklaar ik Technica Engineering GmbH dat het 100BASE T1 MediaConverter NXP TE1600 product voldoet...

Page 20: ...eering GmbH t mto vyhlasuje e produkt Capture Module LIN Combo TE 1170 je v slade so smernicou 2014 30 E pln E vyhl senie o zhode je k dispoz cii na tejto internetovej adrese https technica engineerin...