100BASE-T1 MediaConverter NXP
User Manual
12
3
CONFIGURATION OF THE DEVICE
The 100BASE-T1 MediaConverter is configured by two DIP switches on the front of the
device.
DIP-Switch
Status
Description
1
ON (up)
OFF (down)
100BASE-T1 Port is set to Master
100BASE-T1 Port is set to Slave
2
ON (up)
OFF (down)
100BASE-T1 Port is set to FullOut
100BASE-T1 Port is set to HalfOut
Table 4: Configuration of DIP-Switches
In a 100BASE-T1 Link one device has to be set as Master, the other has to be set
as Slave.
The 100BASE-T1 MediaConverter_NXP should always be set to FullOut. HalfOut
was a former configuration for EMC optimization but it will cause an instable link.