Page 1: ...Manual Version 1 3 Hardware v1 0 and higher USER MANUAL October 2020 Firmware 1 0 0 100 1000BASE T1 MEDIACONVERTER hMTD ...

Page 2: ...cate of Compliance 8 1 4 Scope of delivery 8 1 5 ChangeLog Hardware 8 2 HARDWARE INTERFACES 9 2 1 Connectors 9 2 1 1 RJ 45 Connector 1 9 2 1 2 hMTD Connector 2 9 2 1 3 Power MQS Connector 3 10 2 1 4 Micro HDMI Debug Connector 4 11 2 2 DIP Switches 5 11 2 3 Status LEDs 6 11 2 3 1 Resetting Error LED 11 3 CONFIGURATION OF THE DEVICE 12 3 1 DIP switches 12 3 2 Configuration through Power MQS Connecto...

Page 3: ...100 1000BASE T1 MediaConverter hMTD User Manual 3 8 CHANGELOG 19 9 CONTACT 20 10 DECLARATION OF CONFORMITY 21 ...

Page 4: ...ic and constant delay of about 2 µs 1 1 1 Features 1 Port 100 1000Base T1 Ethernet with Marvell 88Q2112 A2 Transceiver 100 1000 MBit s Fullduplex on a single unshielded twisted pair with hMTD Connector 1 Port 100BASE TX 1000BASE T1 Ethernet with RJ 45 connector Robust steel case 4 DIP Switches for easy configuration Support of 1000BASE T1 IEEE and Marvell Legacy Mode 1 1 2 General Information Volt...

Page 5: ... Technica Engineering s products be operated in voltage ranges beyond those specified in the norms which represents a breach of the conditions of operation then this will void the product warranty and Technica Engineering will assume no liability whatsoever of the results and or consequences thereof This is especially valid whenever the voltage level reaches or exceeds the limits of the low voltag...

Page 6: ...st too high supply voltage protects the device even in case of an internal failure of the Technica Engineering device 1 2 Warranty and Safety Information Before operating the device read this manual thoroughly and retain it for your reference The latest documentation for the 100 1000BASE T1 Media Converter hMTD can be downloaded here https technica engineering de en produkt 100 1000base t1 mediaco...

Page 7: ...ntext when using safety critical systems and must be included in the safety assessment when used The development class in a safety system must be taken into account with standard QM referred to ISO26262 The device can get hot Do not cover the device due to fire danger Do not place the device near to highly flammable materials due to fire danger Do not use the device above the specified operating t...

Page 8: ...ous Substances Directive see Certificate of Compliance on CHAPTER 10 1 4 Scope of delivery The delivery includes 1x 100 1000BASE T1 MediaConverter hMTD Cable set can be ordered separately 1x Cable set o 1m Ethernet Cable o Connectors and crimp contacts o LCA 101 2000 Z Rosenberger Cable Assembly o 4mm banana plugs 1 5 ChangeLog Hardware Version Change Date 1 0 First release Aug 2020 ...

Page 9: ...the front side and backside Figure 2 1 Front side of MediaConverter Figure 2 2 Back side of MediaConverter 2 1 1 RJ 45 Connector 1 This is a standard RJ 45 connector to be used with CAT5e STP cable for 100BASE TX or 1000BASE T connections 2 1 2 hMTD Connector 2 Name Picture Part Number Rosenberger hMTD Stecker E6K10A 1CAZ5 Z Table 2 1 Parts of Tyco hMTD Connector 6 4 5 6 3 2 1 ...

Page 10: ...S 63 header 90deg THR 1 1418888 5 TE connectivity MQS BU GEH 6P 1 969508 2 Distributor mouser de TE connectivity MQS crimp contact 928999 1 Distributors Mouser de Digikey de Table 2 3 Parts of Tyco MQS Connector Pinning Pin Function 1 Reference GND only 2 Link Status Output 3V3 Active High LS 3 Force LinkDown Input Active Low LD 4 ForceSlave Mode Active Low FS 5 Power GND 6 VBAT 6 to 30 Volt DC Ta...

Page 11: ...al operation of the device GP LED General Purpose LED Will be lit when the microcontroller detects an active 100 1000BASE T1 link Error LED red Will be lit when at least one CRC error is detected This may happen when the hMTD connector is plugged during operation Link LED 100 or 1000Base T1 Link active Activity LED 100 or 1000Base T1 Ethernet data transmission Table 2 5 LEDs Description The 100 10...

Page 12: ... function when DIP2 is OFF 4 ON up OFF down Frame Generator active on 100 1000BASE T1 see CHAPTER 3 3 Converting is not working properly during frame generation Normal operation Table 3 1 Configuration of DIP Switches For establishing a BASE T1 link one device must be set as Master the other must be set as Slave It is not possible to mix two speeds of the ports If the MediaConverter is configured ...

Page 13: ...ut of PIN 3 and PIN 1 a full reset of the device will be done 3 2 3 Force Slave mode FS PIN 4 If you connect PIN 4 and PIN 1 by a shortcut wire Force Slave mode is activated These pins are active low There is an integrated 5K Ohm Pullup to 3 3 Volts For normal operation please disconnect the PINs Activated Force Slave mode overrides the DIP switch configuration Force Slave mode must be applied bef...

Page 14: ...00 1000BASE T1 MediaConverter hMTD User Manual 14 The frame contains no specific MAC source or destination All bytes have the same pattern 0xA5 and 0x5A in alternation Figure 3 1 Frame by Frame Generator ...

Page 15: ...n and vice versa DIP Switch 2 100 1000 speed setting is dependent on the speed of the DUT If it is a 100BASE T1 connection DIP Switch 2 must be OFF down and vice versa DIP Switch 3 Legacy IEEE mode setting If the PHY of the DUT is a Marvell PHY A0 Only 1000BASE T1 then the DIP Switch 3 must be OFF down If it is any other IEEE 1000BASE T1 conform PHY the DIP Switch must be ON up DIP Switch 4 Frame ...

Page 16: ...0BASE T1 MediaConverter hMTD User Manual 16 5 USED 100 1000BASE T1 FILTER The following 1000BASE T1 Filter is used in the 100 1000BASE T1 MediaConverter Figure 5 1 Used Filter in 100 1000BASE T1 MediaConverter ...

Page 17: ...100 1000BASE T1 MediaConverter is optimized for automotive use The maximum cable length for 100 1000BASE T1 segments is limited to 15 meters It is not possible to mix up different speeds from RJ 45 to BASE T1 Port Don t use it as Frame Generator while converting Data loss may occur ...

Page 18: ...00 1000BASE T1 MediaConverter hMTD 4 Figure 2 1 Front side of MediaConverter 9 Figure 2 2 Back side of MediaConverter 9 Figure 2 3 hMTD Connector 10 Figure 3 1 Frame by Frame Generator 14 Figure 4 1 Example of a use case 15 Figure 5 1 Used Filter in 100 1000BASE T1 MediaConverter 16 ...

Page 19: ... 19 8 CHANGELOG Version Chapter Description Date 1 0 All First release May 2020 1 1 10 Declaration of Conformity added July 2020 1 2 All Updates Sept 2020 1 3 2 1 Images updated Oct 2020 2 3 1 Resetting Error LED 10 Declaration of conformity updated ...

Page 20: ...ding this product please feel free to contact us Technica Engineering GmbH Leopoldstr 236 80807 München Germany Technical support support technica engineering de General information Info technica engineering de Most current user manuals and product information https technica engineering de en ...

Page 21: ...Technica Engineering GmbH et toode hõivamismoodul 100 1000BASE T1 MediaConverter hMTD TE 1403 vastab direktiivi 2015 863 EU and 2014 30 EL nuetele ELi vastavusdeklaratsiooni tielik tekst on kttesaadav jrgmisel internetiaadressil https technica engineering de wp content uploads 2020 08 100 1000base t1 mediaconverter hmtd te 1403 eu declaration of conformity pdf English Hereby Technica Engineering G...

Page 22: ...nica engineering de wp content uploads 2020 08 100 1000base t1 mediaconverter hmtd te 1403 eu declaration of conformity pdf Malti B dan Technica Engineering GmbH niddikjara li l prodott 100 1000BASE T1 MediaConverter hMTD TE 1403 huwa konformi madDirettiva 2015 863 EU and 2014 30 UE It test kollu tad dikjarazzjoni ta konformit tal UE huwa disponibbli f dan l indirizz talInternet li ġej https techn...

Page 23: ...ednjem spletnem naslovu https technica engineering de wp content uploads 2020 08 100 1000base t1 mediaconverter hmtd te 1403 eu declaration of conformity pdf Slovensky Technica Engineering GmbH týmto vyhlasuje že produkt 100 1000BASE T1 MediaConverter hMTD TE 1403 je v slade so smernicou 2015 863 EU and 2014 30 EÚ Úplné EÚ vyhlásenie o zhode je k dispozícii na tejto internetovej adrese https techn...