Technibel Softy Softy Plus Service Manual Download Page 4

1.Items to be checked

  1 Whetherindo orfan motoris connected withcon nector

a rightway

  2 Whether the input voltage of AC power is right or not

  3 Whether the operation capacitor of indoor fan motor

Is connected with connector 

a rightwayor not

 

2.Flow chart of malfunction diagnosis 

  

  

 

 

 

X8  

in 

 

 

CN10 CN11 in  

 

   

1-2-2 Indoor fan motor does not run

After draw out power supply plug and more five  seconds,
 insert plug again

Replace PCB

PCB failure

Whether input voltage of fan motor is satisfied or not

Whether the core output on controller is normal or not?

Micro-control core failure

Please refer to the description of flow of failure 
                 diagnosis in last page

Whether luminous  diode tube LED lights on or not

Fan capacitor failure

Fan motor failure

Replace indoor fan motor

Replace capacitor

YES

NO

NO

YES

YES

YES

NO

YES

YES

3

Summary of Contents for Softy Softy Plus

Page 1: ...ctions carefully before operating the appliance or carrying out maintenance work Observe all the safety instructions failure to observe the instructions may lead to accidents and or damage Store these...

Page 2: ...airconditionerwillrecovertonormalstatus Under dehumidifying mode air conditioner will control compressor work status automatically according to indoor air temperature under cooling heating or dehumidi...

Page 3: ...PCBboard replacemainPCBboard checkconnectionstatusofcompressor motorandfanmotor pumpingout YES NO YES NO NO Replace PCB NO YES YES Draw out power supply plug and about five seconds later insert again...

Page 4: ...Indoor fan motor does not run After draw out power supply plug and more five seconds insert plug again Replace PCB PCB failure Whether input voltage of fan motor is satisfied or not Whether the core o...

Page 5: ...ore failure Replace button Liquid crystal failure Replace batteries Normal Whether the LCD of remote controller displays normally or not Whether battery voltage is less than 2 5 V or not remote contro...

Page 6: ...ation make sure that conduct wire on circuit panel whether there is jumper loop or not diode location Conduct wire and member are damaged resulting from easy to bend and shock due to coarse treatment...

Page 7: ...nect with power supply Check voltage 1 Whether is there normalAC voltage on XB or not 2 The DC voltage on IC5 input DC12V output DC5V Rectification circuit mistake Drop down transformer does not work...

Page 8: ...hoose the mode according to the environment temperature please choose fan mode to run If under cooling mode the machine continuous running If under dehumidifier mode fan motor and compressor do not wo...

Page 9: ...1111220000000211112032000045 Some models have no content inside dashed frame...

Page 10: ...www technibel com...

Reviews: