5
2-2. Major Component Specifications
2-2-1. Indoor Unit
Indoor Unit MCAV77C5
Controller PCB
Part No. POW-K8E(A), POW-K8E(B)
Controls Microprocessor
Control circuit fuse 250 V 3.15 A
Remote Control Unit RCS-8PS3E
Fan & Fan Motor
Type Cross-flow
Q'ty ... Dia. and length mm 1 ... ø95 / L617
Fan motor model ... Q'ty KFV4Q-11H5P-S ... 1
No. of poles ... rpm (230 V, High) 4 ... 1,130
Nominal output W 10
Coil resistance (Ambient temp. 20°C)
Ω
BRN-WHT : 561.8
VLT-WHT : 197.4
VLT-ORG : 63.4
YEL-ORG : 155.7
YEL-PNK : 115.9
Safety devices Type Internal fuse
Operating temp. Open °C 145±2
Close —
Run capacitor µF 0.6
VAC 440
Flap Motor
Type Stepping motor
Model MP24GA1
Rating DC 12 V
Coil resistance (Ambient temp. 25°C) W WHT – BLU (respectively 4 wires) : 380 ± 7%
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube
Rows 2
Fin pitch mm 1.4
Face area m
2
0.130