(B) Heating
Chart Summary and Explanations
Once the compressor starts, it keeps running for 5 minutes.
If you change the operation mode ( HEAT, DRY, COOL or FAN ) during the heating cycle,
the control circuit stops the compressor for 3 minutes.
the compressor is not controlled by the room sensor.
When set on remote control sensor
Thermo ON: When room temperature is -1°C below the set temperature T°.
Compressor ON
Thermo OFF: When the room temperature is 1°C above the set temperature T°, (T°+1°C)
Compressor OFF
When set on body sensor
Fig. 2
THERMO. ON
THERMO. ON
+1°C
OFF
OFF
2
1. Refer to 2-4 Outdoor Fan Speed Control
OFF
SET SPEED
ON
ON
ON
ON (REVERSING CYCLE)
ON
TEMP.
OPERATION
REMOTE CONTROL
SENSOR
(Only for wireless
remote controller)
BODY SENSOR
OFF
OFF
SET SPEED
SET SPEED
3 SECONDS
ON
OFF
ON
MORE THAN
3 MINUTES
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
3 MINUTES
MORE THAN
5 MINUTES
5 MINUTES
THERMO. ON
THERMO. ON
THERMO. ON
THERMO. ON
2. Refer to 2-2 Cold Draft Prevention (Heating)
BUTTON
COIL (4-WAY)
SOLENOID
E2
TEMP.
COIL
EXCH.
INDOOR HEAT
STANDBY
2
INDOOR FAN
1
OUTDOOR FAN
(H, M or L)
COMPRESSOR
SET. +1°C
SET. -1°
-1 °C
SET TEMP.+4 °C SHIFT
THERMO. OFF
THERMO. OFF
OFF
(31°C)
27°C
25°C
1574_X_S
THERMO. OFF
THERMO. OFF
LL
LL
LL
LL
SETTING TEMP.
SET TEMP.
14