![Technibel Climatisation KPAVM123R5TA Series Installation Manual Download Page 9](http://html1.mh-extra.com/html/technibel-climatisation/kpavm123r5ta-series/kpavm123r5ta-series_installation-manual_1067731009.webp)
8
EG
No.
Accompanying parts
Q’ty
Instruction Manual
1
Tapping screw
1
Tapping screw
1
Vinyl clamp L 150
3
Alarm message label
1
No.
Accompanying parts
Q’ty
Operation controller
1
Indicator section
(do not utilize)
1
Wireless remote controller
1
AAA alkaline battery
1
■
ACCESSORIES
•
Outdoor Unit Cooling only models
5. HOW TO INSTALL THE REMOTE CONTROLLER (OPTIONAL PART)
Run
Timer Heating preparations
Special
screw
4 x 16 mm
TOTA 4 x 16
No.
Accompanying parts
Q’ty
Operation controller
1
Indicator section
(do not utilize)
1
Remote controller
1
Remote controller mounting
1
cradle
Battery
2
•
Outdoor Unit Heat pump models
No.
Accompanying parts
Q’ty
Spacer
2
Instruction Manual
1
Pan-head tapping screw
4
4 x 10
Truss-head tapping screw
2
4 x 16
Vinyl clamp
3
L 150
ALARM MESSAGE LABEL
1
(1)
Fix the operation controller on the metal plate near the
Elec. Junction Box.
Use the provided screws. (fig. 5-1)
(2)
Connect the wireless controller 6 poles wire group with
the one coming from indoor unit indicator section.
Connect the 4 poles wire group to the blue connector
WL of indoor unit PCB. (fig. 5-2)
For Cooling only models, disconnect the white connector CN8
from the indoor unit PCB.(fig. 5-3)
CN8 : LS
5-1
Operation Controller Installation
Fig. 5-1
Fig. 5-2
Fig. 5-3