background image

CAF 187 R5IAA

Power source

Voltage rating

Performance

Capacity
Air circulation 

High/Med./Low

m³/h

Features

Controls/Temperature controls
Control unit
Timer
Fan speed
Airflow direction 

Vertical

Air Filter
Power noise level

High/Med./Low

dB-A

Refrigerant tubing connections
Refrigerant

Narrow tube

mm(in.)

tube diameter

Wide tube

mm(in.)

Refrigerant
Refrigerant tube kit / Air clean filter

Dimensions & Weight

Dimensions                           Unit

Height

mm

Width

mm

Depth

mm

                               Ceiling panel

Height

mm

Width

mm

Depth

mm

Package dimensions            Unit

Height

mm

Width

mm

Depth

mm

Volume

m3

                               Ceiling panel

Height

mm

Width

mm

Depth

mm

Volume

m3

Weight                                 Unit

Net

kg

Shipping

kg

                               Ceiling panel

Net

kg

Shipping

kg

6,35 (1/4)
12,7 (1/2)

ON/OFF 24 hours & Daily program, 1-hour OFF

3 and Auto /1(Hi)

Auto

Washable, Anti-Mold

54/49/46

See catalogue with the requested matching

Microprocessor/ I.C. thermostat 

575

64

R410A

Optional / --------------

273
575

Flare type

790/660/580

220 - 240 V ~  50 Hz

230 V

Wireless remote control unit 

730
730

800

0,18

110
800

380
744
650

4,70

0,07
18,2
22,7
2,50

5

Summary of Contents for 38.7106.005

Page 1: ...5IAA CAF98MR5IAA CAF127R5IAA CAF128MR5IAA CAF187R5IAA 0 8180 533 1 06 2008 SPLIT SYSTEM AIR CONDITIONER Model No Product Code No CAF97R5IAA CAF127R5IAA 38 7106 005 38 7106 006 38 7106 016 38 7106 007...

Page 2: ...w wiring to touch the refrigerant tubing compressor or any moving parts of the fan Do not use multi core cable when wiring the power supply and control lines Use separate cables for each type of line...

Page 3: ...rain Pump and Float Switch 15 5 TEST RUN 16 5 1 How to Test Run the Air Conditioner 16 6 TROUBLESHOOTING 17 6 1 Precaution before Performing Inspection or Repair 17 6 2 Method of Self Diagnostics 18 6...

Page 4: ...filter Dimensions Weight Dimensions Unit Height mm Width mm Depth mm Ceiling panel Height mm Width mm Depth mm Package dimensions Unit Height mm Width mm Depth mm Volume m3 Ceiling panel Height mm Wid...

Page 5: ...ons Unit Height mm Width mm Depth mm Ceiling panel Height mm Width mm Depth mm Package dimensions Unit Height mm Width mm Depth mm Volume m3 Ceiling panel Height mm Width mm Depth mm Volume m3 Weight...

Page 6: ...g temp Open C Close Run capacitor F VAC Flap Motor Type Model Rating Coil resistance Ambient temp 25 C Heat Exch Coil Coil Rows Fin pitch mm face area m2 DATA SUBJECT TO CHANGE WITHOUT NOTICE K35407 M...

Page 7: ...tor F VAC Flap Motor Type Model Rating Coil resistance Ambient temp 25 C Heat Exch Coil Coil Rows Fin pitch mm face area m2 DATA SUBJECT TO CHANGE WITHOUT NOTICE 61 BLU BRN 33 9 39 1 CB XRV184EH Micro...

Page 8: ...g 0 4 l min BI 1300 2725 230 V AC DC 0 5 A PC 309564003 220 240 V 50 Hz 14 W Primary WHT WHT 307 10 Secondary BRN BRN 1 8 10 ATR I55 AC 230 V 50 60 Hz 13 7 V 0 4 A 5 48 VA C7 M3 SY 25 C 60 RH 5 RH 31...

Page 9: ...2 DIMENSIONAL DATA Unit mm REFRIGERANT TUBING JOINT WIDE TUBE CAF97 127R5I CAF98 128MR5I o d 9 52 3 8 CAF187R5I o d 12 7 1 2 9...

Page 10: ...3 ELECTRICAL DATA 3 1 Electric Wiring Diagrams CAF 97 127 R5IAA CAF 187 R5IAA CAF 98 128 MR5IAA 10...

Page 11: ...4 FUNCTIONS 4 1 Operation Functions 11...

Page 12: ...12...

Page 13: ...4 2 Protective Functions 13...

Page 14: ...14...

Page 15: ...4 3 Drain Pump and Float Switch 15...

Page 16: ...5 TEST RUN 5 1 How to Test Run the Air Conditioner display area HIGH POWER button 1HR TIMER button ON OFF operation button 16...

Page 17: ...6 TROUBLESHOOTING 6 1 Precaution before Performing Inspection or Repair 6 2 Method of Self Diagnostics ON OFF button 1HR TIMER button ACL reset button 17...

Page 18: ...ics lamps Since the indications cover various units the corresponding parts listed below may not be present in some models 2 If the self diagnostics function fails to operate OPERATION lamp TIMER lamp...

Page 19: ...6 3 Checking the Indoor and Outdoor Units 19...

Page 20: ...6 4 Noise Malfunction and Electromagnetic Interference 20...

Page 21: ...7 CHECKING ELECTRICAL COMPONENTS 7 1 Measurement of insulation Resistance 21...

Page 22: ...7 2 Checking Continuity of fuse on PCB Assy 7 3 Checking Motor Capacitor 22...

Page 23: ...R D 28 Reyrieux BP 131 01601 Tr voux CEDEX France T l 04 74 00 92 92 Fax 04 74 00 42 00 R C S Bourg en Bresse B 759 200 728...

Reviews: