REPLACING FUSE
In the event that the unit does not function when plugged in, then it is likely that
the fuse has blown. Disconnect from main power before replacing the fuse.
1. Unscrew the ‘Fuseholder Cap’ to reveal the fuse.
2. Remove blown fuse and replace wtih the SAME rating and value.
3. Put the ‘Fuseholder Cap’ back in place.
8
In order to optimize the recovery and recycling of the materials
that old appliances contain and reduce the impact on human
health and the environment, ensure that this product is recycled
at the end of its life.
Master/Slave
1. Connect two or more units with DMX cables.
2. For the master, set DIP Switch 9 & 10 to ON position.
3. For the slaves, set DIP Switch 10 to OFF position.
4. Operate the Wired Remote plugged in the Master to run the whole system.
Wired Remote Control
1. Set DIP Switch 9 & 10 to ON position.
2. Plug in Wired Remote and switch on the machine.
3. Red LED indicator on the Remote is lit up.
4. The following functions are available:
a. Press the yellow TIMER button and yellow LED is lit up. Use INTERVAL knob to adjust
interval from 0- 60 minutes and VOLUME knob for various snow output. The length of snow
generation is 15 seconds.
b. Press the red CONTINUOUS button for continuous generation of snow. You can adjust
snow output with VOLUME knob.
c. Press green MANUAL button for 100% snow output.