background image

 

2

IMPORTANT INFORMATION

 

 
 

Save original packing and documentation for warranty, service and return issues

 
 
Limited Warranty: This warranty covers defects or malfunctions in this equipment.  This warranty lasts for 
a period of two years from date of purchase.  It is the owner’s responsibility to provide invoices for proof 
of  purchase,  purchase  date  and  dealer  or  distributor.    If  purchase  date  can  not  be  provided,  warranty 
period will start at manufacture date.  It is the sole discretion of Techni-Lux to repair or replace parts or 
equipment.   All shipping will be paid by purchaser.  This warranty does not cover lamps, fuses, belts, 
power semiconductors, relays, cleaning, standard maintenance adjustments or normal wear items or any 
problem  resulting  from  the  following:  improper  wiring,  incorrect  voltage  (including  low  or  over  voltage 
conditions  and  lightning),  abuse,  misuse,  improper  maintenance  or  an  act  of  God or damage resulting 
from shipping.  Warranty will be null and void if the product is altered, modified, misused, damaged, or 
subjected to unauthorized repairs.  Lamps are covered by relevant manufacturer warranty. This warranty 
gives you specific legal rights, and you may also have other rights which vary from state to state.  Any 
liability for consequential and incidental damages is expressly disclaimed.  No other warranty, expressed 
or  implied  is  made.    Techni-Lux  liability  in  all  events  is  limited  to,  and  shall  not  exceed,  the  purchase 
price paid. 
 
Returning  equipment  and  Repairs:    All  returns  must  be  accompanied  by  a  Return  Merchandise 
Authorization (RMA) number and sent pre-paid.  Contact the dealer or Techni-Lux directly to obtain an 
RMA.    The  RMA  number  must  be  clearly listed on the shipping label.  Due care must be exercised in 
packing all merchandise to be returned.  All repairs must be accompanied by a written explanation of the 
claimed  problem  or  error  encountered.    Techni-Lux  is  solely  responsible  for  determining  a  product’s 
eligibility  for  coverage  under  warranty.    If  returning  for  consideration  of  credit,  all  accessories  and 
documentation,  original  protective  material  and  cartons  must  be  included  and  the  equipment,  packing 
and  carton  must  be  in  new  resalable  condition.  Credit  for  returned  merchandise  will  be  issued  at  the 
lowest  current  price  and  is  subject  to  a  restocking  fee.    No  returns  accepted  on  discontinued  items.  
Techni-Lux is not responsible for merchandise damaged in transit and reserves the right to refuse any 
return  that  is  damaged  by  the  carrier,  not  accompanied  by  a  Return  Authorization  Number  (RMA#)  or 
sent by freight collect.   
 
Claims:  All claims must be made within seven (7) days of receipt of merchandise.  Any physical damage 
must be reported to carrier upon receipt of merchandise. 
 
 

Please record the following information for future reference: 

 

Model Number:  

TH-SCLPMZ100WW/B or  TH-SCLPMZ100QA/B 

 

 

Serial Number: ________________________________________ 

 

Dealer: ______________________________________________ 

 

Date of Purchase: ______________________________________ 

 
 

www.Techni-Lux.com

 

Summary of Contents for mzSCULPT TH-SCLPMZ100QA/B

Page 1: ...mzSCULPT 100 LED Zoom Profile LED Ellipsoidal Information specifically for TH SCLPMZ100WW B TH SCLPMZ100QA B V1 0 This manual contains important information Please read before operating fixture...

Page 2: ...shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni...

Page 3: ...s 8 Fixture Menu 9 Menu WW Warm White 9 Menu QA Red Blue Green Amber 10 DMX Channel Assignments and Values 10 WW 1 CHANNEL MODE 10 WW 2 CHANNEL MODE 10 QA 5 CHANNEL MODE 11 QA 9 CHANNEL MODE 11 DMX 51...

Page 4: ...40 C Min distance to flammable surface 3 3 ft 1 0 m Min distance to illuminated surface 1 0 ft 0 3 m Electrical Voltage 100 240VAC 50 60Hz Auto Ranging Rated Power 100W Connection NEMA 5 15 3 Pin Edi...

Page 5: ...shipping charges to return products received in non original packing and or cartons Purpose of Manual The purpose of this manual is to explain the necessary steps for using this fixture properly and...

Page 6: ...ting positon on the bracket is provided to alter the mounting height Secure all cables properly and keep away from hot surfaces to prevent heat damage and trip hazards Do not obstruct any vents 1 Colo...

Page 7: ...king Knobs enough to allow Lens Barrel rotation 2 To Rotate a Choose the orientation best suited to the application b Retighten the Lens Barrel Locking Knobs 3 To Remove a Rotate Lens Barrel to hard s...

Page 8: ...of 23 9mm Basic Setup Wiring Diagrams There are two basic ways to use the fixture One is in standalone which does not require the use of any data lines to be connected nor any controller each fixture...

Page 9: ...to change VALUE if present ENTER to Confirm and Save Menu WW Warm White Press ENTER to confirm and save change OPTION VALUE DESCRIPTION dxxx 0 512 DMX Start Address xxx 1CH 1 Channel Mode 2CH 2 Channe...

Page 10: ...Mixed S AA Auto AC and AF Run Mixed Sound Trigger Rxxx 0 255 Red Manual Dimmer gxxx 0 255 Green Manual Dimmer bxxx 0 255 Blue Manual Dimmer axxx 0 255 Amber Manual Dimmer Uxx Firmware Version xx dI x...

Page 11: ...L MODE Channel Function Values 1 Red 0 255 Dimmer 0 100 2 Green 0 255 Dimmer 0 100 3 Blue 0 255 Dimmer 0 100 4 Amber 0 255 Dimmer 0 100 5 Dimmer Curve Speed 0 009 None 10 50 Linear 51 101 Square 102 1...

Page 12: ...ress In this case the fixtures will be slaved together and respond to the same data Because all fixtures see the same data fixtures may be set to any address without concern for the order they are con...

Page 13: ...sses Example Select Start Addresses for 4 fixtures each requiring 3 channels of DMX For this example start with the first unit set to the first possible Start Address 1 This fixture occupies 3 DMX cha...

Page 14: ...revent damaging any internal parts or effects 4 Clean all optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safet...

Page 15: ...rent to the user and is handled by the controller The physical signals are transmitted using a twisted pair of wires and a common shield a configuration called Balanced The controller and all receivin...

Page 16: ...able 30 black w spring snap clip CA XLR5 5 Pre made 5 5 pin XLR Cable CA XLR5 10 Pre made 10 5 pin XLR Cable CA XLR5 15 Pre made 15 5 pin XLR Cable CA XLR5 25 Pre made 25 5 pin XLR Cable CO XLRTERM3 X...

Reviews: