background image

 

2

IMPORTANT INFORMATION

 

 
 

Save original packing and documentation for warranty, service and return issues

 
 
Limited Warranty: This warranty covers defects or malfunctions in this equipment.  This warranty lasts 
for a period of one year from date of purchase.  It is the owner’s responsibility to provide invoices for 
proof of purchase, purchase date and dealer or distributor.  If purchase date can not be provided, 
warranty period will start at manufacture date.  It is the sole discretion of Techni-Lux to repair or replace 
parts or equipment.   All shipping will be paid by purchaser.  This warranty does not cover lamps, fuses, 
belts, power semiconductors, relays, cleaning, standard maintenance adjustments or normal wear items 
or any problem resulting from the following: improper wiring, incorrect voltage (including low or over 
voltage conditions and lightning), abuse, misuse, improper maintenance or an act of God or damage 
resulting from shipping.  Warranty will be null and void if the product is altered, modified, misused, 
damaged, or subjected to unauthorized repairs.  Lamps are covered by relevant manufacturer warranty. 
This warranty gives you specific legal rights, and you may also have other rights which vary from state to 
state.  Any liability for consequential and incidental damages is expressly disclaimed.  No other warranty, 
expressed or implied is made.  Techni-Lux liability in all events is limited to, and shall not exceed, the 
purchase price paid. 
 
Returning equipment and Repairs:  All returns must be accompanied by a Return Merchandise 
Authorization (RMA) number and sent pre-paid.  Contact the dealer or Techni-Lux directly to obtain an 
RMA.  The RMA number must be clearly listed on the shipping label.  Due care must be exercised in 
packing all merchandise to be returned.  All repairs must be accompanied by a written explanation of the 
claimed problem or error encountered.  Techni-Lux is solely responsible for determining a product’s 
eligibility for coverage under warranty.  If returning for consideration of credit, all accessories and 
documentation, original protective material and cartons must be included and the equipment, packing 
and carton must be in new resalable condition. Credit for returned merchandise will be issued at the 
lowest current price and is subject to a restocking fee.  No returns accepted on discontinued items.  
Techni-Lux is not responsible for merchandise damaged in transit and reserves the right to refuse any 
return that is damaged by the carrier, not accompanied by a Return Authorization Number (RMA#) or 
sent by freight collect.   
 
Claims:  All claims must be made within seven (7) days of receipt of merchandise.  Any physical damage 
must be reported to carrier upon receipt of merchandise. 
 
 

Please record the following information for future reference: 
Model Number (circle):  

DL-PANEL1-192U  

 

Serial Number: ________________________________________ 

 

Dealer: ______________________________________________ 

 

Date of Purchase: ______________________________________ 

 

 

www.Techni-Lux.com

 

 

Summary of Contents for DL-PANEL1-192U

Page 1: ...Information specifically for DL PANEL1 192U V1 This manual contains important information Please read before operating fixture...

Page 2: ...to and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or...

Page 3: ...ration Modes 6 Stand Alone Mode 6 DMX Controlling Mode 7 DMX 512 Control 7 DMX Data Connection 7 Data Terminator 8 Adapter 5 to 3 pin 8 DMX Start Address 8 DMX Channel Assignment 9 CH 1 Dimmer 9 CH 2...

Page 4: ...7 x 3 62 Weight 4 5 lbs 2 0 kgs Environmental Location Indoor Max ambient temperature 105 F 40 C Min distance to flammable surface 3 3ft 1m Min distance to illuminated surface 1ft 0 3m Electrical Vol...

Page 5: ...pping Be prepared to provide the model number serial number and description of the nature of the return Shipping damage resulting from inadequate packaging is the customer s responsibility Customer wi...

Page 6: ...ode is selectable by setting the dip switch combination from the information below The DMX mode requires data interconnect cables and a controller to be used The stand alone mode does not require any...

Page 7: ...more than one channel for control will read subsequent channels up to the total number of channels required Since this fixture requires 2 channels of DMX if set to a Start Address of 7 it would use da...

Page 8: ...ssible from the selected start address which does not cause a negative number Continue this process until zero is reached always subtracting the largest possible value that does not cause a negative E...

Page 9: ...3 2 5 and occupy channels 5 thru 6 The last fixture is addressed 5 2 7 and will occupy channels 7 thru 8 Thus 4 fixtures using 2 channels each have Start Addresses of 1 3 5 and 7 and the next free cha...

Page 10: ...optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secure and safe Accessory It...