13
Aug/2017 - V1
Technetix Group Limited
Product User Manual
AIMA3000.ASMM
5.6 ASMM Connections
On the rear panel, connect the:
■
RJ-45 Ethernet Port 0 to a local network switch for network management using Technetix NMSE or a third-party
management software.
■
You can also connect the RJ-45 Ethernet Port 1 of the primary ASMM module to Port 0 on the rear panel of a
secondary/slave ASMM module in another AIMA3000 chassis to create a daisy chain. Although many ASMM modules
can be linked, it is recommended that no more than six be linked to a single master ASMM module within 100 metres.
When operating as a daisy chain, each ASMM's IP address needs to be manually set prior to connecting.
Note:
Alternatively, you can use a LAN cable from a local network switch to Port 0 on the rear panel of a second ASMM module,
to create a daisy chain. In this case, Port 1 on both ASMM modules is not used. See the AIMA3000 system diagram below.
On the front panel, you can connect a:
■
LOCAL RJ-45 Ethernet Port to a laptop PC for detailed configuration tasks via a web page interface (login required).
The default IP address is 192.168.25.168.
■
USB Host Type A connector to a Android device running in USB host mode for initial configuration tasks, such as
setting the AIMA3000’s IP, Net mask and Gateway addresses common to USB and RJ-45. When using the USB Host
Type A connector, the ASMM acts as a client.
Summary of Contents for AIMA3000.ASMM