Page 1: ...AIMA3000 ASMM SYSTEM MANAGEMENT MODULE Online Email customer service vdl technetix com Website technetix com Aug 2017 V1 Technetix Group Limited Product User Manual...

Page 2: ...stics 10 4 1 Block Diagram 10 4 2 Module Appearance 11 4 2 1 Overview 11 4 2 2 Front Panel View 12 4 2 3 Rear Panel View 13 5 Installation 14 5 1 Equipment Inventory 14 5 2 Packing and Transportation...

Page 3: ...Syslog Server 27 7 1 6 User Management 28 7 1 7 Date and Time 29 7 1 8 Factory Defaults 30 7 1 9 Backup and Restore 31 7 1 10 Reboot 32 7 2 Modules Tab 33 7 2 1 ASMM Module 34 7 2 2 Other Modules 34...

Page 4: ...User Manual Technetix NMS3 EPSM Basic Inventory Management Technetix NMS3 EPSM Basic Alarm Management Technetix NMS3 EPSM Basic System Management Technetix NMS3 EPSM Basic Template Management 1 2 Tec...

Page 5: ...p before the cover and the panels of the equipment are installed and the enclosure is closed Modules with USB ports require port covers when not connected Cleaning Only use a damp cloth for cleaning t...

Page 6: ...g There are two fast Ethernet ports on the rear of the module for secondary local control and SNMP communications with Technetix NMSE network management software In addition all modules can be control...

Page 7: ...larm relay contacts Common N C and N O contacts 0 5 A 40 Vac or Vdc maximum Ethernet Ports 0 and 1 RJ45 10 100BaseT Ethernet connectors General Power supply Powered via AIMA3000 backplane Power consum...

Page 8: ...5 Aug 2017 V1 Technetix Group Limited Product User Manual AIMA3000 ASMM 4 Module Characteristics 4 1 Block Diagram...

Page 9: ...6 Aug 2017 V1 Technetix Group Limited Product User Manual AIMA3000 ASMM 4 2 Module Appearance 4 2 1 Overview Front Panel Rear Panel Multi pin Connector...

Page 10: ...dule Item Description 1 Hinged tab plastic face used for removing and locking the module in place 2 LED status indicators see Section 6 3 RST module reset button 4 Orange tab retaining clip 5 LOCAL RJ...

Page 11: ...MM 4 2 3 Rear Panel View Item Description 1 Alarm Relay Contacts COM Common NC Normally Closed NO Normally Open 2 NET MGMT RJ 45 Ethernet Port 0 3 NET MGMT RJ 45 Ethernet Port 1 4 LAN Activity LEDs gr...

Page 12: ...hen transporting This packaging has been specifically designed to protect the equipment 5 3 Power and Cooling Requirements The ASMM module is powered by the power supply module of the AIMA3000 chassis...

Page 13: ...ing for any obvious damage and ensure no screws are missing or loose Check that the module s identifying label is present on the side of the casing Make a note of the module type its serial number and...

Page 14: ...ng the module into the guide rails vertically tilt the module slightly to check that the guides are properly seated on the rails The module is guided to the correct position using the large metal fast...

Page 15: ...il it releases 5 Gently press down on the orange retaining clip to release the hinged tab 6 Lift the hinged tab to remove the module from the multi pin connector 7 Carefully use the hinged tab to init...

Page 16: ...operating as a daisy chain each ASMM s IP address needs to be manually set prior to connecting Note Alternatively you can use a LAN cable from a local network switch to Port 0 on the rear panel of a...

Page 17: ...10 10 10 10 The IP of the client PC must be set to 10 10 10 9 and the front RJ 45 Ethernet port should be used to access the web interface The Backup IP is only supported by hardware version HW_A04259...

Page 18: ...15 Aug 2017 V1 Technetix Group Limited Product User Manual AIMA3000 ASMM 4 Select the tethering and portable hotspot 5 Enable USB tethering...

Page 19: ...eed to be disconnected and reconnected after the ASMM has completed its boot cycle 8 Open the web browser on your Android device 9 Type the default IP address your Android device assigns to clients in...

Page 20: ...are It supports full featured remote provisioning and monitoring of connected application modules with up to 5 trap addresses The SNMP Agent includes MIB Tables and is compatible with the SCTE standar...

Page 21: ...Destinations None set TFTP Server TFTP Server IP Address No initial setting Syslog Server Syslog Server IP Address No initial setting Enable Syslog Export Disable box is unchecked User Management Use...

Page 22: ...x Group Limited Product User Manual AIMA3000 ASMM Restore Configuration using the chosen configuration file Reboot button Reboot will take approximately 15 seconds to complete RF Units dBuV Module Exp...

Page 23: ...l AIMA3000 ASMM 7 1 1 System Information The System page allows for configuring for an ASMM s name location and contact information 7 1 2 Network Configuration The Network Configuration page allows an...

Page 24: ...21 Aug 2017 V1 Technetix Group Limited Product User Manual AIMA3000 ASMM SNMP Configuration The SNMP Configuration page is used to set simple network management protocol traps...

Page 25: ...TFTP Server page allows administrators to specify a TFTP Server for module management This feature only works in conjunction with Technetix NMSE management software NMSE is required for the feature Th...

Page 26: ...anual AIMA3000 ASMM 7 1 4 Syslog Server The Syslog Server page allows administrators to specify an IP address for exporting a system log file This feature only works in conjunction with Technetix NMSE...

Page 27: ...24 Aug 2017 V1 Technetix Group Limited Product User Manual AIMA3000 ASMM 7 1 5 User Management The User Management page allows for additional accounts and permissions to be set created or modified...

Page 28: ...p Limited Product User Manual AIMA3000 ASMM Date and Time The Date and Time page allows administrators to specify a time zone and NTP server allowing the time to be set automatically Note There is no...

Page 29: ...Factory Defaults The Factory Defaults page is used to reset all the module settings It is recommended to backup the current configuration before resetting the ASMM s settings and alarm parameters By...

Page 30: ...iguration file then click the Restore Configuration button to upload It is recommended to make a backup prior to restoring old settings The backup and Restore function will work with a PC that is conn...

Page 31: ...User Manual AIMA3000 ASMM 7 1 8 Reboot The Reboot page allows the ASMM to be restarted by simply clicking the Reboot button 7 1 9 Additional Function Select interface language set the default units an...

Page 32: ...are Manual default no automatic download or upload of configuration settings takes place Auto Download the last saved configuration settings for the same module type are automatically downloaded from...

Page 33: ...arm Control Choose the setting you want then click on the Submit button Table 7 1 ASMM Common parameters not configurable Parameter Units HIHI HI Normal LO LOLO DeadBand Threshold changeable by user D...

Page 34: ...menu bar A vertical list showing all installed modules appears on the left side of the browser window A table to the right of the list shows the current alarm status for all installed modules Click on...

Page 35: ...ule Alarms Detailed alarm information for other module types appear in the associated module s manual 7 4 Logs Tab Click the on the Logs tab on the top menu bar On this page you can view a table showi...

Page 36: ...User Manual AIMA3000 ASMM 7 5 Upgrade Tab Click on the Upgrade tab on the top menu bar On the All Modules page you can view HW FW assembly number and the current FW version of each installed module C...

Page 37: ...rade page Click on the Chose File button then select the file you want to use to upgrade the firmware of the module Click on the Start Upgrade button The upgrade file will need to be located on the PC...

Page 38: ...shing when there is at least one Manual in under Hotswap Mode The mode LED is static green when the slots in Hotswap Mode are all auto mode N A N A N A N A Flashing amber Upgrading ASMM firmware N A N...

Page 39: ...inor Alarm N A N A N A Flashing amber Upgrading PS1 firmware N A N A N A N A Static red HIHI or LOLO PS2 Major alarm N A N A N A N A Static amber HI or LO PS2 minor alarm N A N A N A Flashing amber Up...

Page 40: ...ft column of the Alarms page Factory default alarm settings are shown below ASMM Common parameters not configurable Parameter Units HIHI HI Normal LO LOLO Dead Band Threshold changeable by user Defaul...

Page 41: ...hnetix Manufacturer s Address Technetix Ltd Innovation House Technetix Business Park Albourne West Sussex BN6 9EB Product Name ASMM AIMA System Management Module Conforms to the following standards FC...

Page 42: ...Limited Product User Manual AIMA3000 ASMM Appendix A Default Alarm Limit Settings Formula dBmV 60 dB V dBmV dB V dBmV dB V 10 50 1 61 9 51 2 62 8 52 3 63 7 53 4 64 6 54 5 65 5 55 6 66 4 56 7 67 3 57...

Page 43: ......