Selecting
'Port 1'
below the RFSW module on the left column will open up the port configuration page.
In the port settings page, the switch parameters can be set.
On the
'Port 1'
configuration page, the
'Switch Control'
can be set to:
■
Path A
Input limits can be set by configuring the parameters for the
'Critical Alarm'
and
'Low Alarm'
. When a
'Critical High'
or
'Critical Low'
Alarm occurs, the RFSW will automatically switch to
'Path B'
(when no critical high or low alarms exist
on
'Path B'
).
■
Path B
Input limits can be set by configuring the parameters for the
'Critical Alarm'
and
'Low Alarm'
. When a
'Critical High'
or
'Critical Low'
Alarm occurs, the RFSW will automatically switch to
'Path A'
(when no critical high or low alarms exist
on
'Path A'
).
Setting
Description
Switch Mode
Toggle manual or automatic operation
Wait to Restore Time
After the input has been switched, a timer can be set for
the switch to return it to the default input. It prevents the
switch from continuously toggling between states.
Switch Control
Sets the primary switch port