SYMPTOM
CAUSE
SOLUTION
E1
1.Bad communication
between
the console and the control
board
console and con
The treadmill can’t work and not switch on. Computer
show E1, and cause warning sound.
Cause
:
Bad connection between controller and
computer, check the wiring between the console and
the stand post
,
if the wiring is bad, change the wiring .
E2
Bad connection of the motor
wiring
The treadmill can’t work and not switch on
。
Computer
show E2, other places no showing and cause warning
sound 9 times. Stop the treadmill; and it returns to the
normal appearance, it can start again.
Cause
:
Check the motor wiring and whether there is
bad smell of the controller, if yes, change the
controller.
E3
No speed signal: there is
electricity to the motor, but
there is no signal from the
motor speed more than
3seconds.
The treadmill can’t work and not switch on
。
Computer
show E2, other places no showing and cause warning
sound 9 times. Stop the treadmill, and it return to the
normal appearance, it can start again.
Cause
:
there is no signal more than 3seconds, check
the sensor plug is good or not, make sure it is good or
change it to the good one.
Problem
Possible cause
Corrective action
Treadmill does not
work
a .no connect to power supply
Plug into socket
b. safety switch not insert
Insert safety switch in monitor
c .transformer is not good
Check the transformer
d. the wiring set is burnt
Check the wring set
Suddenly stop
a .safety key off
Put on the safety key
b. system problem
Amend by the technical
Button key no function
a. button key is bad
Change the button
b .all button have no function
a. change the button board
b. change the console board
c. change the console