background image

 

 

Overview: controls & button functions 

 

Monitor 

Power indicator 

ON / OFF button 

View/rotate image button 

Camera 

head 

illumination 

button 

Handle 

Brightness  adjustment  display 
button 

Battery  compartment  (at  the 
back of the device) 

Video-out port 

10  Flexible gooseneck 

 

11  Camera head with LEDs 

 

Inserting & replacing the batteries 

 
Ensure  that  the  camera  is  switched  off.  The  battery  compartment  [8]  is 
located at the back of the device. Remove the battery compartment cover by 
pressing the release mechanism and lifting the cover upwards. The ribbon in 
the  battery  compartment  is  intended  to  facilitate  the  subsequent  removal  of 
the  batteries.  When  inserting  the  batteries,  make  sure  that  this  ribbon  runs 
completely  under  all  4  batteries  and  that  you  can  still  access the  end  of  the 
ribbon after the batteries have been inserted. 
 

 

Insert 4x AA (LR6) batteries 1.5V 
with  the  correct  polarity  in  the 
battery compartment.  
 
Note  the  markings  in  the  battery 
compartment 

and 

on 

the 

batteries. 
 
Remove  the  batteries  if  you  will 
not  be  using  the  device  for  an 
extended period of time. 
 

 
 

Summary of Contents for TX-116

Page 1: ...Do the same with the original accessories for this product In case of warranty please contact the dealer or the store where you bought this product Warranty 2 years Introduction The endoscope camera T...

Page 2: ...able camera illumination 8 stages with 4 white LED lights Easy operation via ON OFF button 3 buttons for 90 image rotation display brightness and endoscope light Lightweight handy design flexible and...

Page 3: ...ice Remove the battery compartment cover by pressing the release mechanism and lifting the cover upwards The ribbon in the battery compartment is intended to facilitate the subsequent removal of the b...

Page 4: ...move any impurities on the rubber ring a and on the screw thread b with a slightly damp cloth To maintain the flexibility of the rubber ring you should lubricate it occasionally for example with vasel...

Page 5: ...htness adjustment display button 7 is pressed again the brightness adjustment is reset to the default value Changing the display The camera image can be rotated by 180 and mirrored vertically or horiz...

Page 6: ...ack device in use for example TV Monitor displays a Battery charge level indicator permanent b LED lighting of the camera head display for 3 seconds when pressing the camera head illumination button 5...

Page 7: ...e a different or better cable Safety instructions Neither the endoscope camera is for medical use nor for use on humans and animals There is a risk of a potentially fatal injury If there is smoke unus...

Page 8: ...of water Consult a doctor immediately Operational safety The housing of the endoscope camera must not be opened because it does not contain any parts that require maintenance Ensure that the device i...

Page 9: ...en a child swallowed a battery go to a doctors place or bring the child into a hospital promptly Look for the right polarity and of batteries Always change all batteries Never use old and new batterie...

Reviews: