sensor InformatIon:
test:
✔
Slide the LUX switch
to SUN position (below is SUN). Slide
the SENS switch
to maximum (below is the maximum). Adjust
the TIME switch, slide 5” switch to ON position. (slide upwards).
✔
Switch on the power; the sensor and its connected lamp will have
no signal at the beginning. After Warm-up 30sec, the sensor can
start work. If the sensor receives the induction signal, the lamp
will turn on. While there is no another induction signal any more,
the load should stop working within 5sec and the lamp would
turn off.
✔
Slide the LUX knob above on the minimum (moon). If the ambient
light is more than 10LUX, the sensor would not work and the
lamp stop working too. If the ambient light is less than 3LUX
(darkness), the sensor would work. Under no induction signal
condition, the sensor should stop working within 5sec.
nIGHt:
motion sensor only works by night
on:
Motion sensor works by day and night
sens:
Adjusts the sensitivity of the motion sensor
time delay:
Sets lighting time after activity between 5/30s or
1/3/5/8min.
note:
when testing in daylight, please turn LUX switch to
(SUN)
position, otherwise the sensor lamp could not work! If the lamp is
more than 60W, the distance between lamp and sensor should be
60cm at least.
Motion sensor works by day and night. For daylight use, set LUX
knob to maximum (SUN) for correct work.
some proBLem and soLVed Way
✔
the product does not work:
a. Please check if the connection of power source and load is
correct.
b. Please check function of the lamp and switch on main fuse after
complete installation.
c. Please check if the settings of working light correspond to
ambient light.
✔
the sensitivity is poor:
a. Please remove objects out from the detection area.
b. Please check if the ambient temperature is too high.
c. Please check if the induction signal source is in the detection
field.
d. Please check if the installation height corresponds to the height
required in the instruction.
✔
the lighting time is not compliance with needed:
a. If the sensor can’t shut off the lamp, please check if the time
delay is set to maximum position
b. Please adjust the lighting time as you need.
Warranty
No guarantee or liability can be accepted for any changes and
modifications of the product or damage caused due to incorrect
use of this product.
connectIon
• Switch off the main fuse.
• Check with a voltage tester to be sure all lines are really stress-
free.
• Install the sensor to wall or ceiling using the installation material
included into the package (see below the installation diagram). At
this, attend to the cable location and its alignment. Also attend to
the detection area and max distance.
• Connect the power and the load according to the connection-
wire diagram below.
Height of installation: 2.2-4m
Detection Distance: Max.6m
Test the sensor as below.
connectIon-WIre dIaGram:
With the CE sign, Techly
®
ensures that the product is conformed to
the basic European standards and directives.
In accordance with the WEEE regulation, electrical and
electronic equipment must not be disposed of with household
waste. It means that used electrical and electronic products
should not be mixed with general household waste. There is a
separate collections system for these products.
EN - 2
WWW.TECHLY.COM
INFRARED MOTION
SENSOR