background image

 

Operation:

 

1.

 

Press

 

ON/OFF

 

key

 

to

 

turn

 

on

 

the

 

scale:

 

‐ 

The

 

scale

 

will

 

display

 

from

 

“0000000”

 

to

 

“9999999”,

 

the

 

voltage,

 

then

 

“0.0g”.

 

Please

 

warm

 

up

 

the

 

scale

 

for

 

at

 

least

 

15

 

minutes

 

in

 

order

 

to

 

weigh

 

more

 

accurately.

   

2.

 

Overload:

 

‐ 

If

 

the

 

weight

 

of

 

the

 

samples

 

exceeds

 

+9

 

digits

 

after

 

a

 

1kg

 

reading

 

than

 

full

 

capacity,

 

the

 

scale

 

will

 

show

 

overload

 

indication

 

“HHHHH”.

 

Please

 

remove

 

some

 

samples.

 

3.

 

Tare:

 

‐ 

Press

 

TARE

 

key,

 

to

 

zero

 

the

 

scales.

 

4.

 

Counting

 

Function:

 

‐ 

Place

 

a

 

select

 

quantity

 

of

 

samples

 

i.e.

 

10,

 

20,

 

etc.

 

onto

 

the

 

plate,

 

then

 

press

 

PCS

 

key

 

for

 

it

 

to

 

go

 

into

 

counting

 

mode.

 

‐ 

Press

 

PCS

 

key

 

and

 

select

 

the

 

sample

 

proportion

 

(10,

 

20,

 

30,…,100)

 

units.

 

‐ 

Press

 

ON/OFF

 

key

 

to

 

confirm.

 

Put

 

samples

 

onto

 

the

 

plate.

 

The

 

scale

 

displays

 

the

 

counting

 

result.

 

Press

 

MODE

 

key

 

to

 

quit

 

the

 

counting

 

mode.

 

NOTE:

 

To

 

change

 

weighing

 

units,

 

after

 

the

 

counting

 

function

 

has

 

been

 

used,

 

the

 

scales

 

must

 

be

 

turned

 

off

 

and

 

back

 

on

 

to

 

reset

 

the

 

units

 

function.

 

 

Calibration:

 

‐ 

Press

 

MODE

 

key

 

for

 

4

 

seconds

 

to

 

go

 

into

 

calibration

 

mode.

 

The

 

display

 

will

 

flash.

 

‐ 

Put

 

a

 

weight

 

on

 

the

 

scale

 

according

 

to

 

the

 

capacity

 

shown,

 

i.e.

 

500g.

 

The

 

unit

 

will

 

display

 

PASS,

 

and

 

the

 

calibration

 

is

 

done.

 

 

 

 

 

 

Other

 

Important

 

Information:

 

‐ 

Please

 

operate

 

the

 

machine

 

according

 

to

 

the

 

technical

 

specifications.

   

‐ 

Use

 

the

 

bubble

 

indicator

 

to

 

ensure

 

scales

 

are

 

level.

 

‐ 

Only

 

use

 

the

 

scales

 

on

 

a

 

clean

 

and

 

stable

 

platform.

 

Make

 

sure

 

the

 

environment

 

is

 

without

 

shock,

 

wind,

 

radiation,

 

and

 

magnetic

 

field.

 

‐ 

If

 

the

 

machine

 

display

 

is

 

not

 

stable,

 

please

 

check

 

the

 

weighing

 

plate

 

is

 

inserted

 

properly

 

into

 

the

 

scale,

 

and

 

make

 

sure

 

there

 

are

 

no

 

obstructions.

   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 