I.1.
Basic terms
Firing
– The cycle starts after the flue gas temperature has reached the defined
value provided that it does not drop below that level for a period of 30 seconds
(factory-set
firing
time).
Operation
– After completion of firing cycle the controller enters the
operation
cycle
and a message reading “
PID:OPERATION
” appears on the display. It is
the basic operation status of the controller where the blowing operation and fuel
feeding are performed automatically following the PID algorithm and the
temperature is fluctuating around the temperature preset by the user. Should
the temperature rise unexpectedly 5°C above the pre-set value a so-called
supervision mode
is activated.
Supervision mode
– It is activated automatically if the temperature exceeds
the pre-set value by more than 5°C in the
operation mode
. In such a case the
controller changes PID operation to manual settings (according to parameters
- 6 -