Tech
set: 5
00
AM, TEMP -10
0
C (temperature change – 10
0
C)
Saturday-Sunday
set: 4
00
PM, temperature 5
0
C (temperature 5
0
C)
set: 5
00
PM, temperature 5
0
C (temperature 5
0
C)
set: 6
00
PM, temperature 5
0
C (temperature 5
0
C)
In this case, if the set valve temperature is 60
0
C, on Monday from 3
00
until 6
00
, the set valve temperature shall drop by 10
0
C every weekday
from Monday to Friday, so it will be 50
0
C. In turn, during weekend
(Saturday, Sunday) from 16
00
C to 19
00
C, the set valve temperature will
increase by 5
0
C, so it will be 65
0
C.
Step three (Mode):
A user activates one of the two previously set modes (
Mode1, Mode2
),
or deactivates the weekly control option completely.
After activating one of the modes, on the controller homepage, in the place
of
preset
text (the preset temperature), the digit with the value of the
currently preset deviation shall be pulsating (informing at the same time
about the weekly control activity).
Function
delete the data
allows to remove the settings of the weekly
program saved before in a simple way, to be able to enter the new settings.
IV.f) Valve 2
If the user wants to control the second valve, like in the previous
case, all settings should be configured in the same manner as in the case of
valve 1.
IV.g) Additional valve 1, additional valve 2
The user has the opportunity to control two additional valves (option),
after buying two independent ST-61 modules.
After connection, each additional module should be
registered
, by
introducing the module number (this number is visible in the casing of module
ST-61). Then, the configuration of an additional valve can be started.
In the case of an additional valve, the following functions should be set:
➢
Activated
(switching-on the valve after the finished configuration)
➢
temperature control
-
21
-