![TECH EU-RI-1 User Manual Download Page 9](http://html.mh-extra.com/html/tech/eu-ri-1/eu-ri-1_user-manual_829132009.webp)
TECH
9
VI.
REGULATOR FUNKTIONS – MENU 1
1.
BLOCK DIAGRAM - REGULATOR MENU
In order to start editing particular parameters, press MENU button. Press the MENU button to choose the parameter to
be edited - the parameter is flashing. In order to change the settings, use the touch buttons PLUS and MINUS. Once the
changes have been introduced, confirm by pressing MENU button (confirm and go on to edit the next parameter).
Changes will also be saved automatically after 5 seconds of inactivity.
2.
CLOCK SETTINGS
After registering the device, the time is updated from the controller (EU-I-2, EU-I-2 Plus, EU-I-3, EU-I-3Plus) to EU-RI-1. By
default, TIM is set to OFF. With the PLUS button you can set TIM to ON and set the time on the regulator. In this case, the
time from the controller will not be taken into account.
In order to set the time, enter the menu and press MENU button until the
clock settings TIM appear on the screen. Use PLUS and MINUS to set the
hour and minutes. Confirm by pressing MENU button (confirm and move on
to edit the next parameter) or EXIT button (confirm and return to the main
screen view). Changes will also be saved automatically after 5 seconds of
inactivity.
Menu
Clock settings
Constant mode
Pre-set day temperature
Day from...
Pre-set night temperature
Night from...
Sensor histeresis
Floor sensor
Underfloor heating hysteresis
Maksimum floor temperature
Minimum floor temperature
Button Lock
Summary of Contents for EU-RI-1