background image

 

10/29/2019 

Tech Works CI-Series Systems Planning & Installation Manual  Page 

3

 of 

42

 

Figures 

 

CI-ODC-1 Operator Desk Console   

 

 

 

4 & 29 

CI-ODC-4 Operator Desk Console   

 

 

 

4 & 33 

CI-HSI-41 Headset Interface   

 

 

 

 

5 & 20 

CI-MSI-22 Microphone Speaker Interface 

 

 

 

5 & 24 

FS-ODC - Operator Foot Switch 

 

 

 

 

FS-1-PLUS 

– Procedure Room Foot Switch  

 

 

CS-520 - 

Dual-Muff, Noise Cancelling Headset 

 

 

CS-540 - Convertible Headset 

 

 

 

 

PRO-42 - Boundary Microphone 

 

 

 

 

PRO-45 Hanging Microphone 

 

 

 

 

MJ-1 - Microphone Jack 

 

 

 

 

 

PRO-SGM - Shotgun Microphone Assembly  

 

 

PRO-ODM - Operator Desk Microphone 

 

 

 

HM-1 Omni-Directional Hidden Microphone   

 

 

System 2 Wall Mount Speaker 

 

 

 

 

System 21 Round Ceiling Mount Speaker 

 

 

 

System 5 Ceiling Speaker 

 

 

 

 

 

PA-402 Paging and Program Amplifier 

 

 

 

PA-SI-1 Paging and Program Speaker Interface 

 

 

PMI-B - Portable Music Interface 

 

 

 

 

CAT6-BB - RJ-45 Cable Breakout Board 

 

 

 

CAT6-* Patch Cord 

 

 

 

 

 

 

PS-2437A - 24VDC @3.7A Power Supply   

 

 

PC-* Power Patch Cable 

 

 

 

 

 

CI-BUSS Connector   

 

 

 

 

 

11 

System Functional Block Diagram 

 

 

 

 

12 

PA-BUSS Connector   

 

 

 

 

 

13 

PA-BUSS Chain 

 

 

 

 

 

 

13 

Selective Gain Reduction, “Ducking”  

 

 

 

15 

Master Slave Connection Diagram   

 

 

 

16 & 39 

Automatic Level Control, ALC 

 

 

 

 

17 

Typical System Wiring Diagram 

 

 

 

 

36-38 

Packaging and Mechanical   

 

 

 

 

39 

CI-BUSS Crossover wiring 

 

 

 

 

 

40 

 

Summary of Contents for PS-2437A

Page 1: ...CI HSI 41 Headset Interface unit the CI ODC 1 Operator Desk Console and many more accessories like foot operated switches The system is based on a sophisticated Automatic Level Control technology whi...

Page 2: ...r own engineering all sections may be useful You may also wish to contact a Tech Works application engineer for assistance feel free we re here for you Table of Contents Page CI BUSS Components 4 Basi...

Page 3: ...7 PRO ODM Operator Desk Microphone 7 HM 1 Omni Directional Hidden Microphone 7 System 2 Wall Mount Speaker 7 System 21 Round Ceiling Mount Speaker 7 System 5 Ceiling Speaker 7 PA 402 Paging and Progra...

Page 4: ...n CI ODC 4 Operator Desk Console The CI ODC 4 allows a single operator location to communicate selectively with up to 4 separate systems in 4 separate rooms It includes a professional cardioid condens...

Page 5: ...ophones speakers and other CI Buss and PA Buss devices By adding a PA 402 the headset conversation can be played over ceiling speakers so observers can hear the conversation CI MSI 22 Microphone Speak...

Page 6: ...DECT technology these headsets provide secure two way communications between the controlled environment and operators Standard controls on either headset operates features of the CI Series system such...

Page 7: ...io source A 6 inch wire pigtail is soldered to the XLR jack so that the filed technician can terminate the field wire without providing a soldering iron Everything you need is included for proper inst...

Page 8: ...ions and there are Application Templates for other common uses The PA 402 is fully protected against overloads The unit automatically recovers when any overload is removed PA SI 1 Speaker Interface Th...

Page 9: ...h Cable designed to connect our Tech Works Collaborative Intercom CI Buss and PA Buss products together These units are designed for the systems integrator to make installation Plug and Play PS 2437A...

Page 10: ...the CI Series has a solution for each professional working in your facility And no one person dictates how the other communicates customizable flexibility is what makes the CI Series Collaborative Int...

Page 11: ...odules to make a custom system CI Buss Active Unit CI Buss Active Unit CI Buss Active Unit CI Buss Active Unit MASTER SLAVE MASTER SLAVE MASTER SLAVE AUDIO AUDIO AUDIO Functional module units are alwa...

Page 12: ...her unit Most system requirements are satisfied with a single Chain Very large system may have several Chains defined as Groups Groups may be joined together by a Hub such as the CI ODC 4 Jumpers insi...

Page 13: ...S Chain POWER AUDIO CONTROL SOURCE AMPLIFIER AMPLIFIER AMPLIFIED SPEAKER SPEAKER AMPLIFIER PA BUSS OUTPUT POWER The Audio Monitoring may be selectable adding together the audio sources as desired A se...

Page 14: ...Pair is a Party Line passing through to all the Units forming an Amplifier Chain The PA BUSS Source is the Initiator of the Alert other units may take appropriate action Responder Units are electrical...

Page 15: ...n Reduction Ducking is used to determine how much to turn down the sound Many intercommunications systems require full Duplex Operation That is several users may be listening and talking at the same t...

Page 16: ...PA 402 may respond by replacing Background Music with Communications Key the ALERT with the CI BUSS and Talk Switch the Music goes away if someone is talking There are hundreds of ways to configure t...

Page 17: ...d with the Microphone Gain Reach Control 16 Position Rotary Switch A Setup Indicator Off if source is muted Green when the Source is keyed Flashing Red when limiting AUDIO INPUT LEVEL VCA AUDIO OUTPUT...

Page 18: ...h a nearly constant output levels Microphone Gain is always setup first Initially the Output level controls should be set to minimum No Output Limiter Setup with a Microphone Always do first Talk into...

Page 19: ...k up so the gain settings can be reduced Minimum Speaker levels to accomplish reliable communications The number of Open Microphones should be kept to a minimum When possible Microphones should be key...

Page 20: ...e ALC has an indicator for the Threshold of Limiting This indicator also serves as a setup indicator for adjusting the Headset microphone levels Front Controls and Indicators MICROPHONES COLLABORATIVE...

Page 21: ...A BUSS MONITOR OUTPUT CI BUSS MASTER OUTPUT HEAD SET 4 HEAD SET 3 HEAD SET 1 HEAD SET 2 PS 2437A POWER SUPPLY Up to 4 CS 540 Headsets FS 1 Plus Foot Switch for Priority Talk FS 1 Plus Foot Switch for...

Page 22: ...plished by turning off the microphone at the Base Station See the Plantronics User s Manual There are three Audio Pathways in the HSI 41 Communications between Headsets Communications on the Collabora...

Page 23: ...gnal is selectable logical OR ed Talk Switch Active TALK_SW ON OFF Operator Microphone is Active OP_MIC_ACTIVE ON OFF Always Overrides other selections ALWAYS ON OFF The Collaboration Buss CI BUSS all...

Page 24: ...CI BUSS ALERT CI BUSS ACTIVE ALC OR SUM LOCAL ALC PA BUSS INPUT MASTER INPUT SLAVE INPUT LISTEN LEVEL DUCK MUX TALK SW CI BUSS ALERT ALWAYS CI BUSS ALERT TALK SW PA BUSS IN ALERT SELECT MUX AMP ALWAYS...

Page 25: ...25 Volts Maximum 10 Watts Maximum Two Position Euro Style Barrier Strip Speaker Microphone Input Four Position Euro Style Barrier Strip Universal Microphone Line Input Shield Switch Common Talk Switch...

Page 26: ...ever they cannot make up for poor acoustic isolation There are two distinct primary resonance modes in most installations One is room resonance one mode is most prevalent such as floor to ceiling reso...

Page 27: ...ion is a Remote Single Location for use with an Operator Console This is a Remote Single Location for use with an Operator Console CI ODC The Power Amplifier is used for a Procedure Room Ceiling Speak...

Page 28: ...ASTER AUDIO INPUT HEADSET EARPHONE HEADSET ON PRE AMP PRE AMP BUFFER OR OR AND SELECT MUX LISTEN LEVEL DUCK MUX SUM AND BUFFER CALL TONE GEN ALWAYS VOX TRIPPED CONSOLE MICROPHONE HEADSET MICROPHONE HE...

Page 29: ...ggle Action with VOX or Momentary when Push to Talk TALK Indicator Red when Microphone is enabled Allows listening without interrupting the Remote Conversation Side Console Speaker Listening Level Kno...

Page 30: ...switch is pushed the indicator goes off to indicate the Console Microphone is disabled When the TALK switch is pushed again the indicator lights red to indicate the Microphone is enabled When the micr...

Page 31: ...r has a Wireless Headset Optional The Wireless Headset has an ON OFF switch when the Headset is Off the function is the same as above The Headset has priority and converses with the Procedure Room whe...

Page 32: ...SELECTED PAGE SWITCH AND ANY STATION SELECTED PTT PRE AMP PRE AMP OR OR AND SELECT MUX CONSOLE LISTEN LEVEL DUCK MUX SUM AND BUFFER ALWAYS VOX TRIPPED CONSOLE MICROPHONE HEADSET MICROPHONE HEADSET ON...

Page 33: ...l audio level Headset On Indicator Green when the Operator Wireless Headset is ON When the Headset is ON the Console Microphone Speaker and Switches are disabled Side Console Speaker Listening Level K...

Page 34: ...ator indicates that station is Calling Selecting a Calling Station cancels that stations Call The Operator may disable the microphone with the TALK Switch to only listen to the Procedure Room When the...

Page 35: ...ve The Headset has priority and converses with the Procedure Room when the HEADSET ON indicator is lighted Red The Console Microphone Speaker and Switches are disabled The Listen and Talk indicators a...

Page 36: ...Headsets and a Background Music System with all of the electronics mounted under the counter in the Observation Room WALL WINDOW COUNTER PSD2437A CAT6 1 PATCH CABLE PC 1 PATCH CABLE CI MSI 22 WM CI HS...

Page 37: ...6 10 PATCH CABLE PC 10 PATCH CABLE HM 1 HIDDEN MICROPHONE BELDEN 8761 TWISTED SHEILD MICROPHONE CABLE OBSERVATION OPERATOR LOCATION BED ROOM SYSTEM 21 CEILING SPEAKERS BED 120VAC LOCATE NEAR THE HEAD...

Page 38: ...N 1325R TWISTED SHEILD MICROPHONE CABLE Simple Bank Teller Window Intercom 24VDC 1 5 A CI MSI 22 Tech Works 1 800 813 1080 WWW TECH4PEOPLE COM CALL SW SPKR SPKR CALL SW CI BUSS SLAVE PA BUSS OUTPUT CO...

Page 39: ...M AND PAGING AMPLIFIER POWER PA 402 LEVEL ACTIVE LEVEL PROGRAM ACTIVE DUAL CHANNEL INTERCOM AMPLIFIER POWER Tech Works Making Specialized Communication Easy IC 52B THRESH CALL OPERATOR REACH LEVEL VOX...

Page 40: ...SLAVE_IN_ 5 SLAVE_IN_ 3 SLAVE_OUT_ 6 SLAVE_OUT_ 8 ALERT_OUT_ NORMAL CI BUSS RJ 45 Cable wired 1 to 1 Ethernet Standard Wiring Signal Pairing 1 2 Control 3 6 Audio 4 5 Audio 7 8 Control TIA 568B COLOR...

Page 41: ...10 29 2019 Tech Works CI Series Systems Planning Installation Manual Page 41 of 42 Notes...

Page 42: ...10 29 2019 Tech Works CI Series Systems Planning Installation Manual Page 42 of 42 Tech Works CI Series Collaborative Intercom System Planning and Installation Manual Back Page...

Reviews: