ROCKY REAR VIEW TANK ASSEMBLY AND PARTS LIST

KEY

PART NO.

DESCRIPTION

UNIT

1

EDT-100

REPLACEMENT DESICANT CARTRIDGE - ELITE

1

2

EPT-100

ELITE PURGE TANK

1

3

ETAR-R

ELITE TANK ANGLE ROCKY - REAR

1

4

ETHR

ELITE TANK HANDLE ROCKY

2

5

EPCB 

ELITE PRECOOLER BRACKET

2

6

CFB-P

COALESCING FILTER BRACKET

1

7

CFAO-375

COALESCING FILTER ASSEMBLY

1

8

ERPCM

ELITE ROCKY PRECOOLER MOUNT

1

9

DPC-1E

ELITE PRECOOLER - SINGLE

1

10

ETAR-F

ELITE TANK ANGLE ROCKY - FRONT

1

11

ERMM

ELITE ROCKY MOTOR MOUNT

1

12

CF-115-230E

ELITE COOLING FAN - DUAL VOLTAGE

2

13

EAAR

ELITE ALTERNATE AIR - ROCKY

1

1

3

2

4

5

7

8

9

6

10

11

12

13

Summary of Contents for ACOR2D1

Page 1: ...Argyle Ave Fresno CA 93727 559 291 1650 800 428 7139 FAX 559 348 9677 TECH WEST INC Manufacturers of Dental Vacuum and Air Systems ELITE SERIES ROCKY COMPRESSOR INSTALLATION AND SERVICE MANUAL Revised...

Page 2: ...ions 4 Elite Series Rocky Start Up 5 Elite Series Rocky Maintenance 6 Elite Series Rocky Compressor Motor Assembly Breakdown 7 8 Coalescing Filter Assembly Breakdown 9 Tank Breakdown 10 Desiccant Drye...

Page 3: ...voltage is not between these values Circuit breaker switches must be 20 amp voltage 2 Local code may require you to provide a quick disconnect safety switch for the compressor 3 See Figure 1 below fo...

Page 4: ...ht otherwise be overlooked Remove cardboard shipping carton b Remove the Oilless Compressor from its shipping skid Inspect the unit for damage Oilless Compressors are shipped bolted to a pallet This p...

Page 5: ...RESSOR INSTALLATION 2 3 CONNECTIONS Figure 2 Dryer Purge Connection Electrical Connection to disconnect and electrical panel 110 v 220 v Alternate Air Connection to fresh air supply Air Out Connection...

Page 6: ...ker from the panel to the ON position c Turn power ON from the toggle switch on the compressor Compressor should run quietly and vibration free The storage tank should start to build pressure d The co...

Page 7: ...dentification number and serial number found on the nameplate located on the front of the unit switch plate Component life operating at continuous duty maximum pressure will shorten the life of the ri...

Page 8: ...9 ROCKY FILTER ASSEMBLY 1 2 3 KEY PART NO DESCRIPTION UNIT 1 CFAO 375 COALESCING FILTER ASSEMBLY 3 8 1 2 CFEO 375 COALESCING FILTER ELEMENT 3 8 1 3 CFBP 375 COALESCING FILTER BOWL 1...

Page 9: ...HR ELITE TANK HANDLE ROCKY 2 5 EPCB ELITE PRECOOLER BRACKET 2 6 CFB P COALESCING FILTER BRACKET 1 7 CFAO 375 COALESCING FILTER ASSEMBLY 1 8 ERPCM ELITE ROCKY PRECOOLER MOUNT 1 9 DPC 1E ELITE PRECOOLER...

Page 10: ...1 4 EDC 100 REPLACEMENT DESSICANT TANK 1 5 MV 250 METERING VALVE 1 6 SN 250 CL STAINLESS STEEL NIPPLE 1 4 3 7 FE 4 6 FLAIR FITTING 1 4 X 3 8 1 8 BV 250 BALL VALVE 1 4 1 9 BT 250 BRASS TEE 1 4 2 10 FPH...

Page 11: ...LVE 1 3 MI 100 MOISTURE INDICATOR 1 4 FA 4 4 1 4 FLARE HOSE FITTING 1 5 POVA 100 POP OFF VALVE 125 PSI ASME 1 6 SSN 375 CL STAINLESS STEEL NIPPLE 3 8 CLOSED 1 7 ATM ALUMINUM TANK MANIFOLD 1 8 FE 4 4 B...

Page 12: ...TOGGLE 13 ELITE ROCKY WIRING DIAGRAMS WIRING DIAGRAM WITH SOUND COVER AND 24v SWITCH 115V...

Page 13: ...SV 115 PURGE VALVE SOLENOID VALVE 115V 1 10 DSV 230 PURGE VALVE SOLENOID VALVE 230V 1 11 CFAO 375 COALESCING FILTER 3 8 1 12 CFEO 375 COALESCING FILTER ELEMENT ONLY 1 13 DPB 100 DRYER PURGE BUCKET 1 1...

Page 14: ...1 16 15 9 10 DUAL ELITE SERIES ROCKY COMPRESSOR 2 2 1 3 4 6 6 7 8 11 12 14 17 18 19 20 21...

Page 15: ...s the moisture indicator pink YES Is intake filter clogged Is there sufficient pressure build up with head discharge line removed YES NO Defective head contact Tech West Note Close shut off valve Pump...

Page 16: ...ONLY A FEW SECONDS YES Does head run with dis charge line disconnected NO Is there suffi cient voltage at disconnect box Blockage in air line locate repair YES Install Tech West transformer NO YES NO...

Page 17: ...Maintenance Service Supplies Service scheduled for Service items needed 22...

Page 18: ...23...

Page 19: ...2625 N Argyle Ave Fresno CA 93727 559 291 1650 800 428 7139 FAX 559 348 9677 TECH WEST INC Manufacturers of Dental Vacuum and Air Systems...