Tech Lighting ELEMENT E4-L A Series Installation Instructions Manual Download Page 1

1

Installation Instructions for

920E4LED-A

Round or Square Element 4" Adjustable Housing

E4_-L_A_

1.2

LED ROUND SQUARE

-

/

G

P

I

:

ENERAL RODUCT NFORMATION

This product is suitable for indoor locations.

This product can be dimmed with a standard electronic dimmer.

This instruction shows a typical installation.

HOUSING CLASP

HOUSING

1B

INNER ADJUSTABLE BAR

OUTER ADJUSTABLE BAR

TAB

STOP POINT

3

3

NAIL

2

Install the Housing with Adjustable Bars

1A

2

3

4

Slide the inner adjustable bar completely through the
three housing clasps. Make sure the nail is on top.

Slide and push the outer adjustable bar completely onto
the inner adjustable bar so that the tab clicks into place
behind the stop point. This will prevent the adjustable bars
from coming apart.

Repeat steps 2 & 3 for the other side of the housing.

BREAK OFF

AND DISCARD

¾” or thicker

½” to ¾”

LEAVE TAB

IN PLACE

Keep Tab for ceiling ½” to ¾” thick.

When using adjustable hanger bars with ½” to ¾” thick
ceilings, leave the tab of the hanger bars in place.

Break off Tab for ceiling ¾” or thicker.

When using adjustable hanger bars with ¾” or thicker
ceilings, remove the tab by bending it at the perforation.

1

NOTE:

Skip this section if installing the housing

with butterfly brackets.

CAUTION RISK OF FIRE

-

This product must be installed in accordance with

the applicable installation code by a person familiar

with the construction and operation of the product

and the hazards involved.

Use minimum 90°c supply conductors.

Summary of Contents for ELEMENT E4-L A Series

Page 1: ...adjustable bar so that the tab clicks into place behind the stop point This will prevent the adjustable bars from coming apart Repeat steps 2 3 for the other side of the housing BREAK OFF AND DISCARD or thicker to LEAVE TAB IN PLACE Keep Tab for ceiling to thick When using adjustable hanger bars with to thick ceilings leave the tab of the hanger bars in place Break off Tab for ceiling or thicker W...

Page 2: ...the nails completely into the joists to secure the adjustable bars 6 7 6 7 Adjust the collar position horizontal position by sliding the housing on adjustable bars When the desired location is achieved tighten the two 6 self tapping screws to lock the housing onto the adjustable bars 8 9 NOTE Notches in the collar can be used to align multiple housings using a laser or string 9 6 SELF TAPPING SCRE...

Page 3: ...e power line wires into the housing electrical box Use the appropriate wiring diagram on the following page to wire your fixture accordingly 2 WARNING RISK OF FIRE When using the housing electrical box for power feed through use 4 12 or 6 14 MAX AWG AWG branch circuit wires 3 3B NOTE When a fixture is installed in a location that requires servicing from below the ceiling through the fixture apertu...

Page 4: ...LACK PURPLE PURPLE DIM DIGITAL BUS DIM DIGITAL BUS EXTERNAL GROUND GROUND GREEN GROUND HOUSING CONNECTOR TO DRIVER EldoLED SOLOdrive DALI EldoLED Driver Wiring DRIVER DRIVER DRIVER IC LABELED FIXTURE WIRING EXTERNAL NEUTRAL EXTERNAL HOT NEUTRAL WHITE HOT BLACK ORANGE WHITE ORANGE DALI CONTROL DALI CONTROL EXTERNAL GROUND GROUND GREEN GROUND HOUSING EldoLED DUALdrive DALI EldoLED Tunable White Wiri...

Page 5: ...CONNECTOR TO DRIVER HOUSING CONNECTOR TO DRIVER Hi Lume 2 Wire DRIVER EXTERNAL GROUND GROUND GREEN EXTERNAL NEUTRAL NEUTRAL WHITE DRIVER DRIVER GROUND EXTERNAL NEUTRAL NEUTRAL WHITE PURPLE PURPLE DIM DIGITAL BUS DIM DIGITAL BUS HOUSING EXTERNAL GROUND GROUND HOUSING Hi Lume Driver Wiring EXTERNAL HOT HOT BLACK EXTERNAL HOT HOT BLACK Hi Lume EcoSystem THERMAL PROBE CONNECTOR TO DRIVER THERMAL PROBE...

Page 6: ...a 4 1 2 diameter circle on drywall Cut out the marked section For square trims mark a 4 1 2 square on drywall Cut out the marked section 1 4 1 2 Insert the plaster ring completely into the collar ceiling and secure them in place with the provided set screws and Allen wrench 1 ROUND PLASTER RING SQUARE PLASTER RING NOTE Longer set screws have been provided for instances where the plaster ring does ...

Page 7: ...p Housing 1 To adjust the height grip the module assembly and push up to minimize glare and flash on the trim Pull down on the module assembly for maximum light output and efficiency 6A MODULE ASSEMBLY MODULE ASSEMBLY Plug the collar with the provided dust shield Properly plaster onto the plaster ring and drywall 2 6C 3 6B LENS LOCK PRESS TO UNLOCK TILT PRESS TO UNLOCK TILT 2 2 5C 2 2 ...

Page 8: ... vertically Lock intervals are 2 5 apart INDICATOR MODULE ASSEMBLY LATCH LATCH NOTE Lamp housing can rotate 361 horizontally 3 Pull the rotation lock out to unlock the lamp housing Rotate the lamp housing horizontally When the desired position is achieved push the rotation back to lock the lamp housing in place 4 6C 3 ROTATION LOCK LATCH CLOSED LATCH LATCH OPEN LATCH ...

Page 9: ...nses Optional 7A Place lenses max 2 optional inside the lens holder spring 1 Line up tabs of the lens holder spring with the notches on the optic holder and push the lens holder spring on 2 7B 2 2 2 LENS HOLDER LENSES ...

Page 10: ...10 Notes ...

Page 11: ...11 Notes ...

Page 12: ...60077 IL 847 410 4400 www element lighting com 2020 Tech Lighting L L C All rights reserved The Element graphic is a registered trademark of Element Element reserves the right to change specifications for product improvements without notification 12 ...