Installation Instructions for
Kable Lite Mini Surface Electronic Transformer
700KLMRT30E_
1
920KLMSET
G
P
I
:
ENERAL RODUCT NFORMATION
This product is ETL listed and suitable only for indoor dry
locations and approved for use at any height above the
finished floor.
A typical installation is shown. Specific installation must be
in accordance with local electrical codes.
This product may be dimmed only with a low voltage
electronic dimmer. Using a dimmer not designed for low
voltage electronic applications may work initially, but could
eventually cause transformer failure and will void the
warranty. The dimmer must be derated as indicated by the
dimmer manufacturer.
This product is intended for use with Tech Lighting low
voltage lighting systems only.
Read all instructions thoroughly. Read "Important Safety
Information" on page 3 before proceeding with the
installation.
S
T
URFACE RANSFORMERS
Important Safety Information
Turn the electrical power off before modifying the lighting
system in any way.
The fixtures used with the system must be identified for
used with the corresponding system.
Minimum volume of the electrical box must be 6 cubic
inches (98 cubic centimeter).
Load the circuit of the remote transformers to no more than
the maximum rated capacity as specified.
To reset the electronic surface transformer, turn the power
off then on (main power, breaker panel, or wall switch).
1
To reduce the risk of fire and burns, do not install this
lighting system where the uninsulated open bus bar
conductors can be shorted or contact any conductive
materials.
When using a Power Extender, refer to the Power Extender
instructions before performing any installations for this
transformer.
To reduce the risk of the system overheating and possibly
causing a fire, make sure all the connections are tight.
Do not install fixture assemblies closer than six inches to
curtains or similarly combustible materials.
CAUTION - RISK OF FIRE
This product must be installed in accordance with
the applicable installation code by a person familiar
with the construction and operation of the product
and the hazards involved.
Use minimum 90°c supply conductors.