The EU-R-9s Plus room regulator is intended to be installed in heating
zones. Its main task is to maintain the pre-set room/floor temperature by
sending a signal to the heating device or the external controller managing
the actuators, when the room/floor temperature is too low. When such a
signal is received, the heating device opens the flow in the thermostatic
valve.
Controller assets:
•
built-in temperature sensor
•
built-in humidity sensor
•
possibility of connecting a floor sensor
•
wall-mountable cover
•
front panel made of glass
The device is controlled with the use of touch
buttons:
EXIT, MENU.
1. Display
2. EXIT –
in the menu, the button is used to return to the main screen
view. In the main screen view, press this button to display the room
temperature value, the floor temperature value and the air humidity
value.
3.
– in the main screen view, press this button to decrease the pre-
set room temperature. In the menu, use this button to adjust the button
lock function.
4.
– in the main screen view, press this button to increase the pre-
set room temperature. In the menu, use this button to adjust the button
lock function.
5. MENU
– press this button to start editing the button lock function.
Hold this button to enter the menu. Then, press the button to navigate
around functions.
How to install the controller
The controller should be installed by a qualified person.
The wire connection is illustrated below:
The EU-R-9s Plus regulator can be mounted on the wall. In order to do
it, put the rear part of the controller into the flush-mounting box in the
wall. Next, insert the regulator and twist it slightly.
How to register a room regulator in a exact
zone
In order to register the EU-R-9s Plus
regulator in a given zone, go to the EU-
L-9/EU-L-9r controller menu and select
Registration in the submenu of a given
zone (Menu > Zones > Zone 1-8 > Type
of sensor / Wired RS). Next, press and
hold the registration button for about 2
seconds.
If the registration process has been
completed successfully, the EU-L-9/
EU-L-9r controller screen displays
an appropriate message to confirm
whereas the room sensor screen
displays Suc. If the room sensor
displays Err, it means that an error has
occurred during the registration process.
NOTE
•
Only one room regulator can be assigned to each zone.
•
If the
Una
message appears (despite correct device registration),
wait for about 4 minutes or force communication again by holding
the registration button for about 2 seconds until the program
version is displayed.
Main screen description
1. Current room / floor temperature (if the floor sensor has been
connected)
2. Time
3. Heating to reach the pre-set value
4. Active button lock
5. Pre-set temperature
6. Room temperature icon (if the humidity value is displayed, the
humidity icon appears)
How to change the pre-set temperature
The pre-set temperature may be adjusted directly from the EU-R-9s Plus
regulator with the use of the buttons:
and
.
When the device is idle, the screen displays current zone temperature.
Press
or
to change the pre-set temperature value - the digits
start flashing.
Menu functions
Press and hold the MENU button to display the regulator functions:
CAL
- the screen displays the current value of the built-in sensor
calibration. The calibration is performed in the main controller and it is
necessary when the room temperature measured by the sensor differs
from the actual temperature.
CAL
- the screen displays current value of the floor sensor calibration.
VER 10
0
- software version - the software version number is necessary
when contacting the service staff.
Button lock - in order to activate the lock, press MENU and select ON
with the use of buttons
. In order to unlock the buttons, press
and hold the buttons
for about 3 seconds. In order to deactivate
the lock altogether, go to the MENU and select OFF.
EU DECLARATION OF CONFORMITY
Hereby, we declare under our sole responsibility that
EU-R-9s Plus
manufactured by TECH STEROWNIKI, head-quartered in Wieprz Biała
Droga 31, 34-122 Wieprz, is compliant with Directive 2014/35/EU of
the European Parliament and of the Council of 26 February 2014 on
the harmonisation of the laws of Member States relating to the making
available on the market of electrical equipment designed for use within
certain voltage limits (EU OJ L 96, of 29.03.2014, p. 357), Directive
2014/30/EU of the European Parliament and of the Council of 26 February
2014 on the harmonisation of the laws of Member States relating to
electromagnetic compatibility (EU OJ L 96 of 29.03.2014, p.79), Directive
2009/125/EC establishing a framework for the setting of ecodesign
requirements for energy-related products as well as the regulation by
the MINISTRY OF ENTREPRENEURSHIP AND TECHNOLOGY of 24 June
2019 amending the regulation concerning the essential requirements
as regards the restriction of the use of certain hazardous substances in
electrical and electronic equipment, implementing provisions of Directive
(EU) 2017/2102 of the European Parliament and of the Council of 15
November 2017 amending Directive 2011/65/EU on the restriction of
the use of certain hazardous substances in electrical and electronic
equipment (OJ L 305, 21.11.2017, p. 8).
For compliance assessment, harmonized standards were used:
PN-EN IEC 60730-2-9:2019-06, PN-EN 60730-1:2016-10.
Wieprz, 05.11.2020
1
3
5
4
2
1
2
3
5
4
6
20 33
22
2
°C
°C
22
5
Czujnik
podłogowy
YE
GN
84 mm
84 mm
14,6 mm
70 mm
Czujnik
podłogowy
YE
GN
Czujnik
podłogowy
YE
GN
YE
GN
YE - yellow
GN - green
+5V - power +5V
GND - ground
EU-L-9R
EU-R-9s PLUS
Czujnik
podłogowy
YE
GN
20 33
22
2
°C
°C
22
5