Description

The EU-R-9s Plus room regulator is intended to be installed in heating 

zones. Its main task is to maintain the pre-set room/floor temperature by 

sending a signal to the heating device or the external controller managing 

the actuators, when the room/floor temperature is too low. When such a 

signal is received, the heating device opens the flow in the thermostatic 

valve. 

Controller assets:

• 

built-in temperature sensor

• 

built-in humidity sensor

• 

possibility of connecting a floor sensor

• 

wall-mountable cover

• 

front panel made of glass

  The  device  is  controlled  with  the  use  of  touch 

buttons:            

EXIT,  MENU. 

1. Display

2. EXIT –

 in the menu, the button is used to return to the main screen 

view.  In  the  main  screen  view,  press  this  button  to  display  the  room 

temperature  value,  the  floor  temperature  value  and    the  air  humidity 

value.

3. 

 

– in the main screen view, press this button to decrease the pre-

set room temperature. In the menu, use this button to adjust the button 

lock function.

4. 

 – in the main screen view, press this button to increase the pre-

set room temperature. In the menu, use this button to adjust the button 

lock function. 

5. MENU

 – press this button to start editing the button lock function. 

Hold this button to enter the menu. Then, press the button to navigate 

around functions.

How to install the controller

The controller should be installed by a qualified person. 

The wire connection is illustrated below:

The EU-R-9s Plus regulator can be mounted on the wall. In order to do 

it, put the rear part of the controller into the flush-mounting box in the 
wall. Next, insert the regulator and twist it slightly. 

How to register a room regulator in a exact 

zone

In  order  to  register  the  EU-R-9s  Plus 

regulator in a given zone, go to the EU-

L-9/EU-L-9r controller menu and select 

Registration in the submenu of a given 

zone (Menu > Zones > Zone 1-8 > Type 

of sensor / Wired RS). Next, press and 

hold the registration button for about 2 

seconds. 

If  the  registration  process  has  been 

completed  successfully,  the  EU-L-9/

EU-L-9r  controller  screen  displays 

an  appropriate  message  to  confirm 

whereas  the  room  sensor  screen 

displays  Suc.  If  the  room  sensor 

displays Err, it means that an error has 

occurred during the registration process. 

 

NOTE

• 

Only one room regulator can be assigned to each zone. 

• 

If the 

Una

 message appears (despite correct device registration), 

wait for about 4 minutes or force communication again by holding 

the  registration  button  for  about  2  seconds  until  the  program 

version is displayed.

Main screen description

1.  Current  room  /  floor  temperature  (if  the  floor  sensor  has  been 

connected) 

2. Time

3. Heating to reach the pre-set value 

4. Active button lock

5. Pre-set temperature

6.  Room  temperature  icon  (if  the  humidity  value  is  displayed,  the 

humidity icon appears)

How to change the pre-set temperature

The pre-set temperature may be adjusted directly from the EU-R-9s Plus 
regulator with the use of the buttons:

 and 

 . 

When the device is idle, the screen displays current zone temperature.  
Press 

 or 

 to change the pre-set temperature value - the digits 

start flashing. 

Menu functions

Press and hold the MENU button to display the regulator functions: 

CAL

  -  the  screen  displays  the  current  value  of  the  built-in  sensor 

calibration. The calibration is  performed in the main controller and it is 

necessary when the room temperature measured by the sensor differs 

from the actual temperature. 

CAL

 

 - the screen displays current value of the floor sensor calibration.

VER 10

0

- software version - the software version number is necessary 

when contacting the service staff. 

 Button lock - in order to activate the lock, press MENU and select ON 

with the use of buttons 

 

. In order to unlock the buttons, press 

and hold the buttons

 for about 3 seconds. In order to deactivate 

the lock altogether, go to the MENU and select OFF.

EU DECLARATION OF CONFORMITY

Hereby,  we  declare  under  our  sole  responsibility  that 

EU-R-9s Plus 

manufactured  by  TECH  STEROWNIKI,  head-quartered  in  Wieprz  Biała 

Droga  31,  34-122  Wieprz,  is  compliant  with  Directive  2014/35/EU  of 

the  European  Parliament  and  of  the  Council  of  26  February  2014  on 

the harmonisation of the laws of Member States relating to the making 

available on the market of electrical equipment designed for use within 

certain  voltage  limits  (EU  OJ  L  96,  of  29.03.2014,  p.  357),  Directive 

2014/30/EU of the European Parliament and of the Council of 26 February 

2014  on  the  harmonisation  of  the  laws  of  Member  States  relating  to 

electromagnetic compatibility (EU OJ L 96 of 29.03.2014, p.79), Directive 

2009/125/EC  establishing  a  framework  for  the  setting  of  ecodesign 

requirements  for  energy-related  products  as  well  as  the  regulation  by 

the  MINISTRY  OF  ENTREPRENEURSHIP  AND  TECHNOLOGY  of  24  June 

2019  amending  the  regulation  concerning  the  essential  requirements 

as regards the restriction of the use of certain hazardous substances in 

electrical and electronic equipment, implementing provisions of Directive 

(EU)  2017/2102  of  the  European  Parliament  and  of  the  Council  of  15 

November  2017  amending  Directive  2011/65/EU  on  the  restriction  of 

the  use  of  certain  hazardous  substances  in  electrical  and  electronic 

equipment (OJ L 305, 21.11.2017, p. 8).

For compliance assessment, harmonized standards were used:

PN-EN IEC 60730-2-9:2019-06, PN-EN 60730-1:2016-10.

Wieprz, 05.11.2020

1

3

5

4

2

1

2

3

5

4

6

20 33

22

2

°C

°C

22

5

Czujnik

podłogowy

YE

GN

84 mm

84 mm

14,6 mm

70 mm

Czujnik

podłogowy

YE

GN

Czujnik

podłogowy

YE

GN

YE

GN

YE - yellow

GN - green

+5V - power +5V

GND - ground

EU-L-9R

EU-R-9s PLUS

Czujnik

podłogowy

YE

GN

20 33

22

2

°C

°C

22

5

registration button

Reviews: