The following functions can be programmed:
1. Dual-flush or single-flush actuation
2. Lighting options
3. Recognition range
4. Trigger range
5. Interval flush
6. Safety flush
7. Pre-flush
8. Cleaning function
9. Factory settings
The app also has a logging function. The most recent flushes and the total
number of flush actions performed are documented under the “
Log
” button.
Connection to the building control technology
The electronics can be triggered by means of the building control technology
(BCT) and also offer the possibility to send an output signal for a performed flush
to the BCT and to document this.
GND
X110
TECE
BCT
X111
flushing IN
potential-free NO contact
I < 10 mA
U < 3 V
X112
flushing OUT
flushing off = high signal
flushing on = low signal
350 ms
V
cc
V
cc
= 3-28 V
I
max
= 5 mA
EN