background image

You may get some warning information as below:

Press        three times for height

The device calculates and shows the result in the major display 

area.

Press       , clear off the result and measuring again if necessary.

Press 

again to exit the mode.

When the meter is in area mode, you can use the add / subtract 

function to total up the area of several surfaces.

Press button        three times till        showing in the display.

Press       to measure the height of the wall first; 

Press       to measure the bottom edge of the first wall, get the 

first area in the major display area; 

Press       to measure the bottom edge of another wall, get the 

sum of these two walls.

Repeat these operations for more walls. Press button      to 

clear the previous measuring result and start new measure-

ment.

When there is no data in the Auxiliary Display area, press   

to exit the mode.

Units:

Press   key to change the reference point. The device 

reference point by default is rear.

Long press      , a second number shows in the screen. User 

can press      or      to adjust the time. Press       to start count 

down, the measure start

when the time turns to 0.

The back light is set to turn on and off automatically. The back 

light can be on for 15s while operating, and it will be shut off 

automatically in 15s when there is no operation to the device.

Long press        button to turn on or off the buzzer.

This function can keep the precision of the device. Instruction: 

Power off, Long press button       , and then press         . Release 

the button       , then "CAL" and a figure shows on the screen. 

User can adjust the figure with button        according to the 

Technology Creates Power

EN
DE
FR
ES

IT

The product is equipped with 3.7V/850mAh lithium battery 

which is built-in and non-removable

Please charge it if it can not be turned on or there is no power 

indication after starting up.

Please use charging adapter with DC5V and 1A to charge it, 

the charging port is the Type C port. (We recommend to use 

phone charger).

The battery icon          will be displayed in scrollable way during 

charging process. The battery icon          will be displayed and 

flashing when the charging process is completed.

Keep it with full power if no operations for a long time; and 

charge it once every half year to avoid the battery damage.

Under off status, press button 

,device  and  laser  get 

starting simultaneously and stand by for measurement.

Under on status, long press button        for 3 seconds to turn the 

device off. The device can also be shut off without any 

operation for 150 seconds.

Long press button     , reset current measurement unit, the 

default unit is: 0.000m There are 6 units for selection

Turn on/off the Instrument

Unit setting

Changing Reference Point

Delay Measurement

Back Light On/Off

Sound On/Off

accuracy of the meter. Adjusting range: -9 to 9mm, then, long 

press button       to save the calibration result.

Turn on the laser beam by short press of the button     under 

measuring mode, press the button     again for single measure-

ment of length, then the measured results displayed in the major 

display area.

Long press button    under measuring mode and enter into 

continuous measuring mode Maximum measuring result 

displays in auxiliary display area, present result displays in 

major display area.Short press button         or        to exit continu-

ous measuring mode.

Press button       ,       shows on the screen. One of the side of 

rectangle blinking on the display, please follow the below 

instructions for area measuring: Press       once for length  

Press       again for width

The device calculates and shows the result in the major display 

area.

The resent measuring result of length is showed in the auxiliary 

display area.Press 

, clear off the result and measuring 

again if necessary. Press        again to exit the mode.

Press button        twice to enter volume measurement mode. A 

       will shows on the top of screen. Please follow the below 

instruction for volume measuring:

Press 

for Length 

Press 

again for Width 

Single Distance Measuring:

Continuous Measuring:

Area Measurement:

Volume Measurement

Painter Function

There are four Pythagoras modes in case that user gets hard 

to reach the target.

1. 

2. 

3. 

Pythagoras

Calculate the length of two legs by measuring the hypote-

nuse and the angle.

Short press        four times, when the hypotenuse of           

blinking,

Press    ,measure the length of hypotenuse (a),and 

calculates the angle (α) between the bevel and the bottom at 

the same time.

Device calculates the horizontal distance (b) and vertical 

height (h).

Calculate the hypotenuse by measuring the length of two 

legs.

Short press         five times, when one leg of           blinking,

Press 

, measure the length of one leg (a) Press        ,

measure the length of another leg (b) Device calculates the 

length of hypotenuse (x)

Press      six times till the one side of blinking on the screen.

Press      ,measure the length of one side (a)

Press      ,measure the length of the median line (b) Press     

, measure the length of another side (c) Device calculates 

the length of the leg in full line (x)

4. 

The device can be used for length addition and subtraction. 

Press 

   to select the function once get the length measur-

ing result.

Short press ,    "+" shows in the major display area, entering 

cumulation mode. Value of last measurement and the result of 

cumulation will be showed on the screen.

Short press ,    "-" shows in the major display area, entering 

regressive mode. Value of last measurement and the result of 

cumulation will be showed on the screen.

Not only length can be calculated in addition and subtraction, 

but area and volume can do the calculation as well. Take area 

as sample:

Area cumulative function: Measure the first area as showing in 

PIC1. Then press button        ,and measure the second area as 

showing in PIC2, there is a "+" in the left bottom. At last, press 

button 

to get the summation result of these two areas 

which is showing in PIC3.

Press     seven times till the hypotenuse of blinking on the 

screen.

Press       ,measure the length of one hypotenuse (a) 

Press       ,measure the length of another hypotenuse (b)

Press       ,measure the length of one leg (c) 

Device calculates the length of the leg in full line (x)

Legs must short than hypotenuse, or there will be "err" 

shows on screen. In order to guarantee the accuracy, please 

make sure all measurements are start from the same point.

Addition / subtraction

Long press button 

for 3s to record your measuring result 

under measuring mode.

It can also record the result under Area, Volume and Pythago-

ras mode. All the calculating records can be saved by the 

device.

Short press button     ,read the records by press button      . 

Short press       to delete recent record and long press       to

clear up all the records. Press       or       to exit record mode.

The angle information is displayed at the top of the screen, and 

the angle measurement range is -90.0° to 90.0° .

Troubleshooting

Read / Delete the Record:

Angle measurement

Info message

Err

Err1

Err2

Err3

Err4

Err5

Err6

Cause

Out of distance 

measurement range

Signal is too weak

Signal is too strong

Low battery voltage

The working 

temperature is 

out of working range

Pythagoras 

measuring error.

Angle sensor error

Depot Repair

Charge the battery

Use the device in 

the specified 

temperature.

Re-measure and 

ensure that 

Hypotenuse is bigger 

than Cathetus.

Solution

Use the device 

within the range

Chose the surface 

with stronger 

reflectance. Use 

the reflecting plate.

Chose the surface 

with weaker 

reflectance. Use the 

reflecting plate.

Note:

 Use a target plate to increase the measurement range 

during daylight or if the target has poor reflection properties.

Typical Tolerance: ±2mm, when reflectivity 100% (white 

surface), environment light <2000 LUX. 25 °C Tolerance is 

usually affected by the distance, reflectivity, and environment 

light etc. It probably gets tolerance around ±

2mm+0.2mm/m

.

Please check if the accessories are completed according to the 

below list.   

The meter should not be stored in high temperature and 

strong humidity environment for long time; if it is not used 

very often, please take out the battery and place the meter in 

the allocated potable bag and store in cool and dry place.

Please keep the device surface cleaning. Wet soft cloth is 

applied to clean dust, but erosion liquid is never allowed to 

use for the meter maintenance. Laser output window and its 

focus lens can be maintained according to maintenance 

procedures for optical device.

- 10 -

Summary of Contents for MTM10B

Page 1: ...Laser Distance Meter www teccpotools com...

Page 2: ...bsite To get your returns processed as quickly as possible please fill this form and include it in your return package If your product is purchased from Amazon Fulfilled channel please contact Amazon...

Page 3: ...itter Please keep it out of reach of children and avoid using by any irrelevant personnel It is strictly prohibited to shoot eyes or other parts of body with the laser it is not allowed take the laser...

Page 4: ...n on Measuring Area Volume Pythagorean Measuring Save Turn off Remove Reference Point Unit Switch Addition Subtraction Sound Power Supply Length Area Volume and Pythagorean Laser on Maximum Auxiliary...

Page 5: ...displayed and flashing when the charging process is completed Keep it with full power if no operations for a long time and charge it once every half year to avoid the battery damage Under off status p...

Page 6: ...there is no operation to the device Long press button to turn on or off the buzzer This function can keep the precision of the device Instruction Power off Long press button and then press Release the...

Page 7: ...a Short press button or to exit continu ous measuring mode Press button shows on the screen One of the side of rectangle blinking on the display please follow the below instructions for area measuring...

Page 8: ...tton three times till showing in the display Press to measure the height of the wall first Press to measure the bottom edge of the first wall get the first area in the major display area Press to meas...

Page 9: ...m at the same time Device calculates the horizontal distance b and vertical height h Calculate the hypotenuse by measuring the length of two legs Short press five times when one leg of blinking Press...

Page 10: ...do the calculation as well Take area as sample Area cumulative function Measure the first area as showing in PIC1 Then press button and measure the second area as showing in PIC2 there is a in the lef...

Page 11: ...ras mode All the calculating records can be saved by the device Short press button read the records by press button Short press to delete recent record and long press to clear up all the records Pres...

Page 12: ...ry voltage The working temperature is out of working range Pythagoras measuring error Angle sensor error Depot Repair Charge the battery Use the device in the specified temperature Re measure and ensu...

Page 13: ...ce measurement precision Continuous measurement function Area measurement function Volume measurement function Pythagorean proposition measurement function Add and subtract measurement function Min Ma...

Page 14: ...emperature and strong humidity environment for long time if it is not used very often please take out the battery and place the meter in the allocated potable bag and store in cool and dry place Pleas...

Page 15: ...potools com Shenzhen Allsight E business Co Ltd Website www teccpotools com E mail support teccpotools com ADD Room 104 Building P09 South ChinaCity Electronic Trading Center Longgang District Shenzhe...

Reviews: