You may get some warning information as below:
Press three times for height
The device calculates and shows the result in the major display
area.
Press , clear off the result and measuring again if necessary.
Press
again to exit the mode.
●
When the meter is in area mode, you can use the add / subtract
function to total up the area of several surfaces.
Press button three times till showing in the display.
Press to measure the height of the wall first;
Press to measure the bottom edge of the first wall, get the
first area in the major display area;
Press to measure the bottom edge of another wall, get the
sum of these two walls.
Repeat these operations for more walls. Press button to
clear the previous measuring result and start new measure-
ment.
When there is no data in the Auxiliary Display area, press
to exit the mode.
Units:
●
Press key to change the reference point. The device
reference point by default is rear.
●
Long press , a second number shows in the screen. User
can press or to adjust the time. Press to start count
down, the measure start
when the time turns to 0.
●
The back light is set to turn on and off automatically. The back
light can be on for 15s while operating, and it will be shut off
automatically in 15s when there is no operation to the device.
●
Long press button to turn on or off the buzzer.
This function can keep the precision of the device. Instruction:
Power off, Long press button , and then press . Release
the button , then "CAL" and a figure shows on the screen.
User can adjust the figure with button according to the
Technology Creates Power
EN
DE
FR
ES
IT
The product is equipped with 3.7V/850mAh lithium battery
which is built-in and non-removable
Please charge it if it can not be turned on or there is no power
indication after starting up.
Please use charging adapter with DC5V and 1A to charge it,
the charging port is the Type C port. (We recommend to use
phone charger).
The battery icon will be displayed in scrollable way during
charging process. The battery icon will be displayed and
flashing when the charging process is completed.
Keep it with full power if no operations for a long time; and
charge it once every half year to avoid the battery damage.
●
Under off status, press button
,device and laser get
starting simultaneously and stand by for measurement.
Under on status, long press button for 3 seconds to turn the
device off. The device can also be shut off without any
operation for 150 seconds.
●
Long press button , reset current measurement unit, the
default unit is: 0.000m There are 6 units for selection
Turn on/off the Instrument
Unit setting
Changing Reference Point
Delay Measurement
Back Light On/Off
Sound On/Off
accuracy of the meter. Adjusting range: -9 to 9mm, then, long
press button to save the calibration result.
●
Turn on the laser beam by short press of the button under
measuring mode, press the button again for single measure-
ment of length, then the measured results displayed in the major
display area.
●
Long press button under measuring mode and enter into
continuous measuring mode Maximum measuring result
displays in auxiliary display area, present result displays in
major display area.Short press button or to exit continu-
ous measuring mode.
●
Press button , shows on the screen. One of the side of
rectangle blinking on the display, please follow the below
instructions for area measuring: Press once for length
Press again for width
The device calculates and shows the result in the major display
area.
The resent measuring result of length is showed in the auxiliary
display area.Press
, clear off the result and measuring
again if necessary. Press again to exit the mode.
●
Press button twice to enter volume measurement mode. A
will shows on the top of screen. Please follow the below
instruction for volume measuring:
Press
for Length
Press
again for Width
Single Distance Measuring:
Continuous Measuring:
Area Measurement:
Volume Measurement
Painter Function
●
There are four Pythagoras modes in case that user gets hard
to reach the target.
1.
2.
3.
Pythagoras
Calculate the length of two legs by measuring the hypote-
nuse and the angle.
Short press four times, when the hypotenuse of
blinking,
Press ,measure the length of hypotenuse (a),and
calculates the angle (α) between the bevel and the bottom at
the same time.
Device calculates the horizontal distance (b) and vertical
height (h).
Calculate the hypotenuse by measuring the length of two
legs.
Short press five times, when one leg of blinking,
Press
, measure the length of one leg (a) Press ,
measure the length of another leg (b) Device calculates the
length of hypotenuse (x)
Press six times till the one side of blinking on the screen.
Press ,measure the length of one side (a)
Press ,measure the length of the median line (b) Press
, measure the length of another side (c) Device calculates
the length of the leg in full line (x)
4.
●
The device can be used for length addition and subtraction.
Press
to select the function once get the length measur-
ing result.
Short press , "+" shows in the major display area, entering
cumulation mode. Value of last measurement and the result of
cumulation will be showed on the screen.
Short press , "-" shows in the major display area, entering
regressive mode. Value of last measurement and the result of
cumulation will be showed on the screen.
Not only length can be calculated in addition and subtraction,
but area and volume can do the calculation as well. Take area
as sample:
Area cumulative function: Measure the first area as showing in
PIC1. Then press button ,and measure the second area as
showing in PIC2, there is a "+" in the left bottom. At last, press
button
to get the summation result of these two areas
which is showing in PIC3.
Press seven times till the hypotenuse of blinking on the
screen.
Press ,measure the length of one hypotenuse (a)
Press ,measure the length of another hypotenuse (b)
Press ,measure the length of one leg (c)
Device calculates the length of the leg in full line (x)
Legs must short than hypotenuse, or there will be "err"
shows on screen. In order to guarantee the accuracy, please
make sure all measurements are start from the same point.
Addition / subtraction
Long press button
for 3s to record your measuring result
under measuring mode.
It can also record the result under Area, Volume and Pythago-
ras mode. All the calculating records can be saved by the
device.
●
Short press button ,read the records by press button .
Short press to delete recent record and long press to
clear up all the records. Press or to exit record mode.
●
The angle information is displayed at the top of the screen, and
the angle measurement range is -90.0° to 90.0° .
Troubleshooting
Read / Delete the Record:
Angle measurement
Info message
Err
Err1
Err2
Err3
Err4
Err5
Err6
Cause
Out of distance
measurement range
Signal is too weak
Signal is too strong
Low battery voltage
The working
temperature is
out of working range
Pythagoras
measuring error.
Angle sensor error
Depot Repair
Charge the battery
Use the device in
the specified
temperature.
Re-measure and
ensure that
Hypotenuse is bigger
than Cathetus.
Solution
Use the device
within the range
Chose the surface
with stronger
reflectance. Use
the reflecting plate.
Chose the surface
with weaker
reflectance. Use the
reflecting plate.
Note:
Use a target plate to increase the measurement range
during daylight or if the target has poor reflection properties.
Typical Tolerance: ±2mm, when reflectivity 100% (white
surface), environment light <2000 LUX. 25 °C Tolerance is
usually affected by the distance, reflectivity, and environment
light etc. It probably gets tolerance around ±
(
2mm+0.2mm/m
)
.
●
●
Please check if the accessories are completed according to the
below list.
The meter should not be stored in high temperature and
strong humidity environment for long time; if it is not used
very often, please take out the battery and place the meter in
the allocated potable bag and store in cool and dry place.
Please keep the device surface cleaning. Wet soft cloth is
applied to clean dust, but erosion liquid is never allowed to
use for the meter maintenance. Laser output window and its
focus lens can be maintained according to maintenance
procedures for optical device.
- 10 -