Tecamp Raptor Top Manual Download Page 2

Important Safety InStructIonS

The apparatus shall not be exposed to dripping or splashing and that 

no objects with liquids, such as vases, shall be placed on the appara-

tus. The MAINS plug is used as the disconnect device, the disconnect 

device shall remain readily operable.

Warning: the user shall not place this apparatus in the area during 

the operation so that the mains switch can be easily accessible.

1.  Read these instructions before operating this apparatus.

2.  Keep these instructions for future reference.

3.  Heed all warnings to ensure safe operation.

4.  Follow all instructions provided in this document.

5.  Do not use this apparatus near water or in locations where con-

densation may occur.

6.  Clean only with dry cloth. Do not use aerosol or liquid cleaners. 

Unplug this apparatus before cleaning.

7.  Do not block any of the ventilation openings. Install in accordance 

with the manufacturer’s instructions.

8.  Do not install near any heat sources such as radiators, heat 

registers, stoves, or other apparatus (including amplifiers) that 

produce heat.

9.  Do not defeat the safety purpose of the polarized or grounding-

type plug. A polarized plug has two blades with one wider than 

the other. A grounding type plug has two blades and a third 

grounding prong. The wide blade or the third prong is provided 

for your safety. If the provided plug does not into your outlet, 

consult an electrician for replacement of the obsolete outlet.

10. Protect the power cord from being walked on or pinched particu-

larly at plug, convenience receptacles, and the point where they 

exit from the apparatus.

11. Only use attachments/accessories specified by the manufacturer.

12. Use only with a cart, stand, tripod, bracket, or table specified 

by the manufacturer, or sold with the apparatus. When a cart is 

used, use caution when moving the cart/apparatus combination 

to avoid injury from tipover.

13. When a cart is used, use caution when moving the cart/appara-

tus combination to avoid injury from tipover.

14. Unplug this apparatus during lighting storms or when unused for 

long periods of time.

15. Refer all servicing to qualified service personnel. Servicing is re-

quired when the apparatus has been damaged in any way, such 

as power-supply cord or plug is damaged, liquid has been spilled 

or objects have fallen into the apparatus, the apparatus has been 

exposed to rain or moisture, does not operate normally, or has 

been dropped.

cautIon:

 Use of controls or adjustments or performance of proce-

dures other than those may result in hazardous radiation exposure.

WARNING: To reduce the risk of FIRE or electric shock, do

not expose this apparatus to rain or moisture.

cautIon:

 RISK OF ELECTRIC SHOCK DO NOT OPEN

cautIon:

 TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT 

REMOVE COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE 

REFER SERVICING TO QUALIFIED PERSONNEL

The lightning flash with arrowhead symbol, within an 

equilateral triangle, is intended to alert the user to the 

presence of uninsulated “dangerous voltage” within 

the product’ s enclosure that may be of suficient magni-

tude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is 

intended to alert the user to the presence of important 

operating and maintenance (servicing) instructions in 

the literature accompanying the appliance.

!

Summary of Contents for Raptor Top

Page 1: ...Raptor T op Manual...

Page 2: ...they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with a cart stand tripod bracket or table specified by the manufacturer or sold with the app...

Page 3: ...deal for Traveling around the World shows the Vol tage selector switch with between 230 and 115 V can be switched The result is a stunning live performance with an unbeatable sound The meticulous qual...

Page 4: ...ing the taper of the pot the GAIN control can be brought up to a higher position now 3 GAIN This control along with the Input or 10DB inputs adjusts the basic signal level in the valve preamp and thus...

Page 5: ...200 Hz At this frequency the low mid may to each be raised or lowered 15dB This controller generates when turning up the right Kick to the bass sound in the band structure further come forward to lea...

Page 6: ...to wait at least 30 seconds before turning on the BREAK switch as this time lessens the shock on cold tubes thus pro longing their life substan tially With the BREAK switch in the upward position no...

Page 7: ...er switch is used to turn the RAPTOR on and off Before you turn the amp on do make sure that the BREAK switch is in the off position up Activating the PO WER SWITCH will illuminate the TecAmp logo 11...

Page 8: ...uters you can get at any electronics music or computer store Never remove or otherwise attempt to defeat the ground pin of the power cord in order to get rid of a hum induced by a ground loop 13 VOLTA...

Page 9: ...ngaged 18 DI OUT The RAPTOR supplies a transformer balanced line output signal for connecting to a house mixing board recording console or external amplifier s with balanced inputs The need for an add...

Page 10: ...kers must set the impedance selector to 4 ohms When using two 4 ohm cabs the impedance selector mus set to 2 Ohms If you use four 8 ohm the impedance selector mus set to 2 Ohms Attention The Raptor ha...

Page 11: ...dBu impedance EFFFECTS LOOP EFFECT SEND 2 kOhm EFFECT RETURN LINE IN 100 kOhm nominal output 0 dBu impedance LINE OUT 600 Ohm Nennpegel LINE OUT 6 db impedance DI 600 Ohm nominal output DI 6 dBu tone...

Page 12: ...Alter Bahnhofsweg 5 D 35745 Herborn Fon 49 0 2777 6391 e Mail info tecamp de www tecamp de Madein Germany...

Reviews: