Dimensions: (WxHxD)                             approx 11.75” x 11.75” x 5”
Volatage                                                  120v 60 Hz
Ambient temperature                             -4 °F to 131°F
Protection class                                       IP54
Max Switched current                             10 A
Weight                                                     18 lbs
Maximum pulse frequency
for the external used flow meter            240 Hz 
Maximum failure elevationof the
used measuring equipment 
-    for a flow meter                                 0,1%
-    for a level sensor                               1%                  

OVERVIEW

GO WITH THE FLOW.

DESCRIPTION

INTENDED USE

PERMITTED MEDIA

TECHNICAL DATA

The Wonder Box consists of the HDA eco automatic dispenser, which is mounted in a sheet metal housing.
The built-in HDA eco automatic dispenser is optimised for the administration of small and medium-sized 
vehicle fleets and enables the administration of up to 10,000 transactions/2000 users /2000 vehicles.

Optional, additional components to create an entire tank system are the feed pump, the flow meter,  the 
dispensing hose with an automatic nozzle and, if applicable, an analogous level probe or fill level switch 
for monitoring the level in the tank.

The Wonder Box is designed as a Fluid Inventory Control System for use in industry, service centers, filling 
stations and similar facilities.
It is intended for the control of dispensing during the refuelling  of vehicles with liquid and pumpable op-
erating media.

The installation and operation of the Wonder Box in explosion hazardous areas is not permitted. This 
would constitute a risk of explosion.

All liquid and pumpable operating media including diesel, fuels, chemicals, oils, water, heating oil, coolant, 
DEF, windshield washer.
Please check the safety data sheet for your medium.

In the case that the medium generates explosion hazards, the user has to make sure that the used addi-
tional equipment (e.g. pump and meter) and the electrical and mechanical installation follows the national 
regulations of explosion protection

   www.tecalemitUSA.com  I  [email protected]     

    

      

                                

Tel +1-281-446-7300 I Fax 281-619-5613

INVENTORY MANAGEMENT

+

LAN

Wi-Fi

Summary of Contents for WONDERBOX Gen II US110500700

Page 1: ...GO WITH THE FLOW Part US110500700 www tecalemitUSA com I support tecalemitUSA com Tel 1 281 446 7300 I Fax 281 619 5613 HARDWARE INSTALLATION WONDERBOX QUICK GUIDE SERVICE GEN II LAN Wi Fi ...

Page 2: ... nozzle and if applicable an analogous level probe or fill level switch for monitoring the level in the tank The Wonder Box is designed as a Fluid Inventory Control System for use in industry service centers filling stations and similar facilities It is intended for the control of dispensing during the refuelling of vehicles with liquid and pumpable op erating media The installation and operation ...

Page 3: ... LCD DISPLAY KEYPAD PULSE FLOW METER DATA CABLE NOZZLE SWITCH POWER TO PUMP PROBE MAIN LINE IN www tecalemitUSA com I support tecalemitUSA com Tel 1 281 446 7300 I Fax 281 619 5613 EXTERIOR I O Wi Fi antenna LAN Wi Fi ...

Page 4: ...TH THE FLOW ELECTRICAL BOARD www tecalemitUSA com I support tecalemitUSA com Tel 1 281 446 7300 I Fax 281 619 5613 Green Signal Brown Ground Yellow Power White Signal Hot lead Ground Neutral Hot lead Neutral ...

Page 5: ...on Socket modem 6 5 4 3 2 1 PE N PE PU PU N PE L L 1 VT PI GND NS GND LS LS To Nozzle switch Power to pump To contactor Neutral Ethernet CAT 5 100m 328ft max Hot lead Existing pump power line from breaker Electrical board Level Probe White Signal Brown Ground Note Contactor provided with Wonderbox New clean line from breaker box Wi Fi LAN RJ45 Chip To Printer USB only FMT 3 US253590106 Yellow Powe...

Reviews: