teca HP-1200FF Product Information Packet Download Page 3

FEATURES

• Compact, (only 15”L X 7.35”W X 8.17”D)
• Weighs only 21 lbs. (9.5 kg)
• Excels in high ambient temperatures
• Environmentally safe
• Dual voltage versions available
• No compressor, fluorocarbons or filters
• Virtually maintenance-free operation
• Stainless steel exterior housing
• Versions to withstand corrosive environments,

shock and vibration

• Mounts and operates in any orientation

AHP-1200 Air Conditioner

Air Cooled

120 VAC, 240 VAC Input

Thru Mount

NEMA-12, 4,4X

SPECIFICATIONS

OPERATING

OPERATING

PERFORMANCE

VOLTAGE

CURRENT

WEIGHT

TEMP.

AMBIENT

ENCLOSURE

AGENCY

MODEL

PART NUMBER

RATING

VAC

AMPS.

LBS.(KG)

CONTROL

TEMPERATURE

TEMPERATURE

APPROVALS

BTU/HR

50/60HZ 

AMBIENT °C

RANGE °C

AHP-1200FF

0-3090-0-000

500-550

120

4.0

21(9.5)

None

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1200FF

0-3080-0-000

500-550

120

4.0

21(9.5)

TC-6F

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1200FF

0-30F0-0-000

500-550

120

4.0

21(9.5)

85°F (30°C)

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1200FF

0-3050-0-000

500-550

120

4.0

21(9.5)

EXT*

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1200FFHC

0-3030-1-000

500-550

120

4.0

21(9.5)

TC-3F

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1200FFHC

0-3050-1-000

500-550

120

4.0

21(9.5)

EXT*

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1201FF

0-3081-0-000

500-550

120/240

4.0/2.2

29(13.2)

TC-6F

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1201FF

0-3051-0-000

500-550

120/240

4.0/2.2

29(13.2)

EXT*

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1201FF

0-30F1-0-000

500-550

120/240

4.0/2.2

29(13.2)

85°F (30°C)

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1201FFHC

0-3031-1-000

500-550

120/240

4.0/2.2

29(13.2)

TC-3F

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1201FFHC

0-3051-1-000

500-550

120/240

4.0/2.2

29(13.2)

EXT*

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1200XE

0-3080-4-000

500-550

120

5.0

23(10.4)

TC-6F

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1200XE

0-3050-4-000

500-550

120

5.0

23(10.4)

EXT*

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1200XE

0-30F0-4-000

500-550

120

5.0

23(10.4)

85°F (30°C)

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1200XEHC

0-3030-5-000

500-550

120

5.0

23(10.4)

TC-3F

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1200XEHC

0-3050-5-000

500-550

120

5.0

23(10.4)

EXT*

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1202XE

0-3082-4-000

500-550

240

2.5

30(13.6)

TC-6F

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1202XE

0-3052-4-000

500-550

240

2.5

30(13.6)

EXT*

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1202XE

0-30F2-4-000

500-550

240

2.5

30(13.6)

85°F (30°C)

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1202XEHC

0-3032-5-000

500-550

240

2.5

30(13.6)

TC-3F

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1202XEHC

0-3052-5-000

500-550

240

2.5

30(13.6)

EXT*

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1200X

0-3090-2-000

500-550

120

4.0

23(10.4)

None

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1200X

0-3080-2-000

500-550

120

4.0

23(10.4)

TC-6F

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1200X

0-3050-2-000

500-550

120

4.0

23(10.4)

EXT*

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1200X

0-30F0-2-000

500-550

120

4.0

23(10.4)

85°F (30°C)

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1200XHC

0-3030-3-000

500-550

120

4.0

23(10.4)

TC-3F

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1200XHC

0-3050-3-000

500-550

120

4.0

23(10.4)

EXT*

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1200XM

0-3080-2-100

500-550

120

4.0

23(10.4)

TC-6F

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1200XM

0-3050-2-100

500-550

120

4.0

23(10.4)

EXT*

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1200XMHC

0-3030-3-001

500-550

120

4.0

23(10.4)

TC-3F

-40/+70

-10/+60

UL1995/CSA22.2

AHP-1200XMHC

0-3050-3-001

500-550

120

4.0

23(10.4)

EXT*

-40/+70

-10/+60

UL1995/CSA22.2

*

Unit is set for 5-32 VDC external signal, relay(s) included

32

TECA

1-888-TECA-USA (832-2872)

www.teca-usa.com

INCLUDES

• Adjustable temperature control
• Gasket and mounting hardware
• Power input line cord

N

E

M

A

12

N

E

M

A

4

N

E

M

A

4X

OPTIONS

• Other temperature settings for single set point controls
• Custom finishes

catalog 2011 working on.qxp  8/10/2011  2:27 PM  Page 32

Summary of Contents for HP-1200FF

Page 1: ...lly before installation Only qualified technicians should install this equipment If you have any questions regarding your equipment please do not hesitate to call us at 773 342 4900 and we will be happy to assist you We are open from 8 00 am 4 30 pm Central Time Included in this packet you will find Installation Notes for Air Conditioners Product Literature and Specifications Assembly Drawing 1200...

Page 2: ...t is often the most difficult to protect from condensation in this orientation due to the fin orientation gravity and any susceptible components below If a drip pan is employed by the end user use caution to place the pan far enough away from the internal fan to minimize the restriction of air flow The pan should cover the fin ends as well as the fan area When there is a choice the vertical orient...

Page 3: ... UL1995 CSA22 2 AHP 1200XE 0 3050 4 000 500 550 120 5 0 23 10 4 EXT 40 70 10 60 UL1995 CSA22 2 AHP 1200XE 0 30F0 4 000 500 550 120 5 0 23 10 4 85 F 30 C 40 70 10 60 UL1995 CSA22 2 AHP 1200XEHC 0 3030 5 000 500 550 120 5 0 23 10 4 TC 3F 40 70 10 60 UL1995 CSA22 2 AHP 1200XEHC 0 3050 5 000 500 550 120 5 0 23 10 4 EXT 40 70 10 60 UL1995 CSA22 2 AHP 1202XE 0 3082 4 000 500 550 240 2 5 30 13 6 TC 6F 40...

Page 4: ...C Enclosure Air y 266x 39 5 y 266x 41 0 y 266x 42 5 Cold Sink y 173x 39 5 y 173x 41 0 y 173x 42 5 MOUNTING STYLE Thru Mount ENVIRONMENTS SERVED NEMA 12 IP 52 NEMA 4 4X IP 56 RATING TRADITIONAL 530 BTU hr 0 F T 670 BTU hr 20 F T RATING DIN 3168 154 Watts L35 L35 100 Watts L35 L50 See page 10 AHP 1200 Air Conditioner Air Cooled Air Flow Pattern ...

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ......

Page 9: ...ree of charge to Buyer or credit to buyer the price of the defective products ALL OTHER WARRANTIES EXPRESS OR IMPLIED ARE EXCLUDED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL TECA BE LIABLE FOR ANY CLAIM BASED UPON BREACH OF EXPRESS OR IMPLIED WARRANTY OR ANY OTHER DAMAGES WHETHER SPECIAL INDIRECT INCIDENTAL CONSEQUE...

Reviews: