background image

 

Sayfa 

13

 / 

21

 

 

not block the entrance of the pellet to fire pot and start your appliance 
normally. In this mode it will start with pellet as to wood catch the fire then 
auger stops pellet feding and your appliance runs on wood. If the flame starts 
to decrease  add some wood.  Do not keep the door open more than 20 
seconds, otherwise it will go in extiguishing phase. 

 
 

Work Thermostat Setting 

 

 

 

 
 

Click button 

P3 

or 

P4

: the display 

D3 

blinks  

With other click of the buttons 

P3 / P4 

the value of the thermostat is 

increased or decreased  
After 3 seconds the new value is memorised and the display shows as normal  

 

 

 

 
 
 
 
 
 

Manual Pellet Loading  

 
 

 

 

Summary of Contents for TP-24

Page 1: ... 352 321 28 12 www teba com tr KAYSERI TURKEY F AX 90 352 321 28 14 teba teba com trİMALATCI Installation and User Manual Pellet Wood Boiler Model TP 24 TP 35 Tested according to DIN EN 14785 Type BA 1 For product efficiency and emission values see the declaration of conformity TR ...

Page 2: ...l Panel 10 5 1 Buttons and their functions 10 11 5 2 Symbols 11 12 5 3 Error codes and their explanation 12 13 14 5 4 Menu functions 15 5 4 1 Settings menu 14 5 4 1 1 Combustion menu 14 15 5 4 1 2 Heat management menu 15 5 4 1 3 Timer menu 16 17 5 4 1 4 Manual loading menu 5 4 1 5 Wood burning 6 0 Cleaning and maintnance 19 6 1 Heat exhanger cleaning 20 6 2 Ash bin cleaning 20 6 3 Fire pot cleanin...

Page 3: ...AIWA and TEBA brands The products has succesfully passed the official tests Average efficiency of our products is nearly 92 By the 2014 April we started serial production and started to sell in domestic market and export If you are reading this document most probably you are an owner of DAIWA or TEBA brand pellet stove or boiler Please read this manual carefully This manual contains useful informa...

Page 4: ...ermal efficiency 94 Electric 230Volt 50Hz Weight 177kg Boiler capacity 50lt 3 0 WARNINGS USE ONLY 6MM NATURAL PELLETS MANUFACTURED ACCORDING TO DIN PLUS STANDARTS DO NOT USE 8MM OR 10 MM PELET AND SEEDS CLEAN THE FIRE POT EVERYDAY HEAT EXCHANGER PIPES MUST BE CLEANED IN 3 4 DAY PERIODS BY THE BRUSH SUPPLIED WITH YOUR STOVE OR BOILER IF YOU ARE NOT GOING TO USE YOUR PRODUCT FOR A LONG TIME GENERAL ...

Page 5: ...hall not pay for damages 4 2 SAFETY Product must be installed by an authorized person The floor where you are going to install your product must stand the weight of the product If the floor is made of combustible material please use glass metal or marble base under the product Install you product in a well ventilated area The product must be connected to separate chimney not to commenly used chimn...

Page 6: ...tallation must be done by an authorized person Pellet stove or boiler is a fully automatic product Expansion vessel circulation pump thermostates safety valve safety switches are readily installed inside ste product Ignition is made by a resistance and fuel is fed by an auger 4 3 INSTALLATION Radiators must be connected to the boiler by an authorized pesrson The material used in piping must have a...

Page 7: ...ing to the weather conditions of the region where the boiler is being used it is recomended to use 1 3 portion antifreeze against coorosion and freezing 4 3 1 Electric Your product must be connected to 230V 50 Hz electric system Damages caused by non regular electric are not covered by warranty 4 3 2 Flue pipe connection It is recommended to use stainless steel flue pipe Pellet stoves must not con...

Page 8: ...Sayfa 8 21 4 3 3 Minimum Safety Distances ...

Page 9: ...ove 80 cm There mustn t be any combustible material within 80 cm 80cm from the door of the stove This distance would be 40cm if a fire protection panel is placed between the stoves door and the material If the stove is to be placed on a fire sensitive floor fire protective base like marble glass or metal should be used Minimum dimensions of a base is specified below D 50 cm from the door to edge o...

Page 10: ... Igniter Resistance ON L7 Chrono Program enabled L8 Pump ON DISPLAY Display Fix Blinking D1 Time D2 Work Combustion Power set Combustion power change D3 Room Thermostat set Room Thermostat change BUTTONS Click P click Long Pressure P long P1 Display other data Ignition Extinguishing Block Reset P2 Combustion Power Setting Manual Pellet Loading P3 Thermostat Setting Pellet Loading Correction ...

Page 11: ...k Encoder Error No Encoder Signal in case of P25 1 or 2 Block Encoder Error Combustion Fan regulation failed in case of P25 1 or 2 Block Failed Ignition Block Lack of Voltage Supply Block Lack of Fuel Block DAY and TIME not correct due to prolonged absence of power supply Block Anomaly in probe control during Check Up phase Block Extinguishing for water over Temperature Block Low pressure in to th...

Page 12: ...gnalled by the blinking led L3 The Extinguishing finished OFF state is signalled by the fix led L3 Combustion Power Setting Click button P2 the display D2 blinks With other click of the button P2 the power is changed according to the values Ex 1 2 3 4 5 A A Automatic Combustion After 3 seconds the new value is memorised and the display shows as normal Wood burning Combustion power 5 is adjusted to...

Page 13: ...ce runs on wood If the flame starts to decrease add some wood Do not keep the door open more than 20 seconds otherwise it will go in extiguishing phase Work Thermostat Setting Click button P3 or P4 the display D3 blinks With other click of the buttons P3 P4 the value of the thermostat is increased or decreased After 3 seconds the new value is memorised and the display shows as normal Manual Pellet...

Page 14: ...ops automatically after 300 seconds Pellet Loading Correction The long pressure of button P2 activates the Pellet Manual Loading with activation of Auger engine in continuous way The bottom display shows the actual function The up display shows the passed loading time To stop the loading push any button The loading stops automatically after 300 seconds Combustion Fan Speed Correction The activatio...

Page 15: ...ation P1 tA Room buffer temperature tF Exhausting Temperature UF Combustion Fan Speed RPM Volt HF02 Product Code User s Menu 2 Push contemporary the buttons P2 and P4 for three seconds to enter into User Menu 2 To scroll the Menu push the buttons P3 or P4 To enter in a submenu push the button P2 To modify the blinking value push the button P3 to increase or P4 to decrease To exit push the button P...

Page 16: ...s to schedule the 3 time bands available for every day of the week Select Push the button P2 to enter Use the buttons P3 P4 to visualize the time bands set The upper display visualizes the TIME SET if the BAND is disabled The bottom display visualizes DAY BAND ON OFF The long press ure of the button P1 Enables Disables the selected time band PROGRAM CHRONO ACROSS MIDNIGHT Set the time ON for the p...

Page 17: ... day at 23 59 Set the time ON for the next day at 00 00 Set the time OFF for the next day to the wanted value Example 6 30 The system will turn ON on Tuesday at 20 30 and will turn OFF on Wednesday at 6 30 Time and Date It allows to set the current day and time ...

Page 18: ...5 3 1 ASH BIN CLEANING The ash bin under the fire pot should be cleaned daily Your product is equipped with two ash bin The second ash bin is located behid the ash bin that you see under the fire pot To clean the second ash bin remove the ash bin Picture 1 then remove the second ash bin Picture 2 3 4 Second ash bin should be cleaned mothly ...

Page 19: ... that your product is cool then open the door carefully so that the ashes do not spill around Clean inside the fire chamber by a vacuum cleaner refer to picture2 After vacuum cleaning clean the fire pot with a metal brush as shown in picture1 ...

Page 20: ... place 7 0 GENERAL WARRANTY POLICY ARAL MAKİNA MADENİ EŞYA SAN VE TİC LTD ŞTİ warrants the product against the production faults for 2 two years period from the date of installation Invoice of the product must be presented to the authorised technical service to include the product in warranty Pump glass electronic ...

Page 21: ...parts by the manufacturer drops the warranty Service will be given also after warranty period If you have any complain about your product please call your local dealer Prior to call please note the information written on the label fixed at the back of your product The manufacturer keeps the right to make changes in the product after the publication of this manual DATE MANUFACTURER ARAL MAKİNA MADE...

Reviews: