![Team SWR-1180 KA Operating Instruction Download Page 2](http://html2.mh-extra.com/html/team/swr-1180-ka/swr-1180-ka_operating-instruction_3947933002.webp)
Operating Instruction for the SWR/Power-meter
TEAM SWR-1180 KA
This instrument is used to measure SWR and transmit power with two pointers.
The measurement of the SWR is possible in the frequency range of 1.8 - 60 MHz.
For the output power testing there are two ranges available: 20 and 200 W.
In addition the power measuring can be switched to peak and average indication. That is important for
SSB power measuring.
The use of two instruments provide direct reading of the SWR and transmit power values without
switching to forward and reflect.
Note: Power measurement can be made only in the frequency range from 26 to 30 MHz.
The display illumination can be switched on and off.
Front view
Rear view
Installation for SWR and power measurement:
Connect the transceiver to the
[ Transm. ]
connector on the rear panel with a short coaxial cable ( 50
Ω
, approx. 60 cm ) and the antenna to the antenna connector
[ Antenne ]
. Now the instrument is well
installed for SWR and power measurement.
If the SWR value is higher than 2 : 1, please tune your antenna or check the antenna system for any
faults.
Art.-Nr.:
CB
6422
Technical Data:
Frequency range:
1.8 - 60 MHz
Impedance:
50
Ω
SWR scale range:
1 : 5
Power range
forward:
20 / 200 W
reflected:
5 / 50 W
Accuracy: better
than
±
3 %
Size:
130
×
80
×
116 mm
Weight:
ca.
835
g
DC consumption:
110 mA
Description:
1)
For exact power measurement please use
only a 50
Ω
load at the antenna connector.
2)
The left scale indicates the forward power
and the output power of the transceiver.
3)
The right scale indicates the reflected
power of the antenna.
4)
The cross-point of the two scales indicates
the effective SWR value.