Mode Programming:
Program mode function table:
Mode function name
Description
Default
Setting
1.Running Mode
- Forward with brake, Forward/Reverse,Forward//Reverse
with brake
Fwd/ brake
Fwd/Brake/Rev
(XPS EL)
2.Low voltage protection
2.0V~8.4V --- 0.1V/step
6.3V
3.
Dead band
0~30% --- 1%/Step
10%
4.
Over heat Cut
On/Off On
5.
Reverse Force
1~100% --- 1%/Step, higher value have higher reverse force
90%
6.
Brake PWM Frequency
Level 1~4, higher level have higher brake frequency
2
7.
Brake force
1~100% --- 1%/Step, higher value have higher brake force
90%
8.
Drag Brake
1~100% --- 1%/Step, higher value have higher drag brake
force
9%
2%
(XPS EL)
9.
Forward PWM Frequency
Level 1~4, higher level have higher forward frequency
3
10.
Punch level
0~100% --- 1%/Step, higher value have more initial punch
0%
11.
Power Band
1~100% --- 1%/Step, higher value have higher overall
power band
100%
12.
Start RPM
1000~100000 --- 1000/Step, RPM to start the Timing Boost
5000
13. Timing Burst
1~100% --- 1%/Step, how fast achieve the max timing
boost value. Higher value allows faster Timing Boost
70%
14.Timing Boost
1~100% --- 1%/Step, higher value have more advance
Timing, in term to make the motor having higher RPM
0%
15. Turbo Delay
0.1~1s --- 0.1s/Step, higher value with longer time to start
up the turbo function
0.1s
16. Turbo Boost
1~100% --- 1%/Step, higher value have more advance turbo
Timing, in term to make the motor having higher RPM
0%
Notes:
The maximum sum value of Turbo Boost and Timing Boost cannot be set more than 100%. For
example, if the Timing Boost is set at 80%, then the max Turbo Boost should be set at 20%. In other words,
if the Turbo Boost is set at 50%, the max Timing Boost should be set at 50%.