09 DW
Channel monitoring with activated radion function - On / Off
While the radio is on, the selected channel is monitored. Upon reception of a signal, the radio is
deactivated until the signal disappears.
10 LAMP
Illumination of the LCD - OFF / KEY / CONT
OFF
: no illumination
KEY
: after entry, the display is illuminated for 5 seconds
CONT
: illumination is constantly on
11 LOCK
Key lock
settings: - K + S / PTT / KEY / ALL
Press the keylock key (keypad, lower row to the right) to activated or deactivate the keylock
function. The activated state is indicated by a key symbol in the upper left corner.
K + S
: all key of the keypad, as well as the channel selection keys are locked - PTT key, as
well as the monitor and programmable function keys are activated
PTT
: transmission is blocked - the display shows
P LOCK
KEY
: all keys of the keypad are locked - channel selection keys, as well as PTT, monitor
and programmable function keys are activated
ALL
: all functions are locked
12 MSGSET
Programming of the welcome message that appears shorty after turning on the radio
5 symbols are available:
a) blank character,
b) the digits
0 - 9
,
c) the letters
A - Z
and
d) the symbols
asterix *
,
underscore _
and
plus +
.
Select the symbols with the channel selection keys.
To proceed to the next space press the number key
9
. To move the cursor backwards press the
number key
7
.
To delete the actual entry press the
V/M
key (keypad, lower row left side).
13 NAME
display types are FREQ and ALPHA
ALPHA
: The programmed frequency is displayed as a channel number, e.g.
CH - 001
.
FREQ
: The programmed channel name is displayed. If no channel name is programmed,
the channel number is shown.
14 NM SET
Channel Name -
Programming of the welcome text that appears after turning the radio on. The text message can
contain a maximum of five symbols composed out of :
a) blank character,
b) the digits
0 - 9
,
c) the letters
A - Z
and
d) the symbols
asterix *
,
underscore _
and
plus +
.
Select the symbols with the channel selection keys.
To proceed to the next space press the number key
9
. To move the cursor backwards press the
number key
7
.
To delete the actual entry press the
V/M
key (keypad, lower row left side).
15 OFFSET
not available
16 OPN MSG
temporary message after turning the radio on - OFF / MSG / DC
OFF
: no message text is displayed
MSG
: in 12 MSGSET programmed text is displayed
DC
: voltage of the battery pack
17 PSWD
password protection - On / Off
Requires entry of the programmed password if function is activated. The password is program-
med via software or directly at the radio via the menu function 18 PSWD W.
The radio cannot be operated if the correct password is not entered.
A forgotten password can be retrieved via software.
18 PSWD W
password creation
Create a 4-digit password out of the numbers 0 - 9. Confirm your entry by pressing the
F
key
(keypad, lower row right side).
To delete the entry press the
V/M
key (keypad, lower row left side).
19 ROGER
roger beep - On / Off
In the activated state, the three-tone roger beep is sent after release of the PTT key (9).
20 SCN MD
there are three scan modes available :
TO : Time-Operated-Scan
Is an occupied channels scanned, remains the radio for a certain period of time, which is
programmable via software, on this channel before scanning is continued regardless if the
signal is still present or not.
CO : Carrier-Operated-Scan
The radio remains on an occupied channel until the signal ends. Then, scanning continous.
SE : Search-Scan
Is an occupied channel scanned, stops the scan function and the radio remains on this channel.
22
23
English