Daily cleaning

1. Switch off the unit.
2. Drain the TEALtainer II completely and dispose of 

all water to a sluice or foul water drain. 

3. Flush out the waste compartment (red cap) with 

fresh water.

4. Re-fill the fresh water compartment (white cap).
5. Wipe all surfaces with a soft cloth using a mild 

detergent.

6. Switch on and the unit will automatically run a 10 

second cold water purge.

Disinfection

It is recommended that your Hygienius is disinfected 

every 48 hours. Fill the fresh water compartment, add 
500ppm chlorate solution and switch on. After the 
automatic 10 second purge, press the purge button. 
The unit will run for 5 minutes effectively disinfecting 
the complete system. Dispose of all the water and 
then flush through with clean water.

Storage

Before placing in storage:-

•  Operate the purge button until water flow stops.
•  Empty the TEALtainer II

 

completely, clean and 

wipe down.

•  Ensure that the unit is protected from frost.

HYGIENIUS user manual

Getting started

Your Hygienius

 

provides a hot water hand wash 

without external plumbing or drainage. It is entirely 

self contained, with the TEALtainer II holding 10 litres 

of fresh water. The waste water is contained within 

a heavy duty polyethytene bag - when the fresh is 

used up the waste bag will be full. The Hygienius

 

provides up to 50 ten second washes per filling of the 

TEALtainer II.
Please note:- The Hygienius

 

has nothing to adjust. 

Both the water temperature (approx. 42ºC) and the 10 

second wash are factory set. 

Unpacking

Check that the component parts and specification are 

correct. Check for damage and retain packaging.  

Notify Teal immediately if damage is found.

Setup

Disconnect the water delivery pipe from the blue 

ringed connector and remove TEALtainer II. Fill with 

cold water though the large opening up to the side 

indentation. Place the TEALtainer II into the unit and 

feed the waste pipe back into the red waste cap hole 

and connect up the water delivery pipe.
Connect the 13 amp plug into the 230V mains socket 

and switch the unit on by means of the ON/OFF switch 

located on the underside of the power box behind the 

door. The Bluesensor will light up and the unit will run 

a 10 second cold water purge. The Hygienius is now 

ready for use.

Operation 

To operate, place your hands in the bowl by the 

sensor and the Bluesensor will start to flash, indicating 

that the water is being heated. After 3-5 seconds, the 

Bluesensor will extinguish and the hot water spray will 

run for 10 seconds. To reset, remove the hands from 

the bowl and the Bluesensor will light up indicating 

that your Hygienius is ready for further use.

Purge button

Fresh water 

compartment

Bluesensor

TEALtainer II

Fresh water 

delivery 

connector

Red cap 

waste water 

bag