Daily cleaning
1. Switch off the unit.
2. Drain the TEALtainer II completely and dispose of
all water to a sluice or foul water drain.
3. Flush out the waste compartment (red cap) with
fresh water.
4. Re-fill the fresh water compartment (white cap).
5. Wipe all surfaces with a soft cloth using a mild
detergent.
6. Switch on and the unit will automatically run a 10
second cold water purge.
Disinfection
It is recommended that your Hygienius is disinfected
every 48 hours. Fill the fresh water compartment, add
500ppm chlorate solution and switch on. After the
automatic 10 second purge, press the purge button.
The unit will run for 5 minutes effectively disinfecting
the complete system. Dispose of all the water and
then flush through with clean water.
Storage
Before placing in storage:-
• Operate the purge button until water flow stops.
• Empty the TEALtainer II
completely, clean and
wipe down.
• Ensure that the unit is protected from frost.
HYGIENIUS user manual
Getting started
Your Hygienius
provides a hot water hand wash
without external plumbing or drainage. It is entirely
self contained, with the TEALtainer II holding 10 litres
of fresh water. The waste water is contained within
a heavy duty polyethytene bag - when the fresh is
used up the waste bag will be full. The Hygienius
provides up to 50 ten second washes per filling of the
TEALtainer II.
Please note:- The Hygienius
has nothing to adjust.
Both the water temperature (approx. 42ºC) and the 10
second wash are factory set.
Unpacking
Check that the component parts and specification are
correct. Check for damage and retain packaging.
Notify Teal immediately if damage is found.
Setup
Disconnect the water delivery pipe from the blue
ringed connector and remove TEALtainer II. Fill with
cold water though the large opening up to the side
indentation. Place the TEALtainer II into the unit and
feed the waste pipe back into the red waste cap hole
and connect up the water delivery pipe.
Connect the 13 amp plug into the 230V mains socket
and switch the unit on by means of the ON/OFF switch
located on the underside of the power box behind the
door. The Bluesensor will light up and the unit will run
a 10 second cold water purge. The Hygienius is now
ready for use.
Operation
To operate, place your hands in the bowl by the
sensor and the Bluesensor will start to flash, indicating
that the water is being heated. After 3-5 seconds, the
Bluesensor will extinguish and the hot water spray will
run for 10 seconds. To reset, remove the hands from
the bowl and the Bluesensor will light up indicating
that your Hygienius is ready for further use.
Purge button
Fresh water
compartment
Bluesensor
TEALtainer II
Fresh water
delivery
connector
Red cap
waste water
bag