Precautions when placing loads on the
unit
o
Make sure the load is perpendicular to the surface to
which this unit is attached.
o
Apply the load so that it is centered on the center of
the unit. If the load is not centered (eccentric load),
twisting, for example, and measurement errors could
occur. This could even result in damage.
F1
F2
F
F is the correct load orientation
F1 is an eccentric inclined load
F2 is an eccentric load
o
If the load receiving area is contacted by something that
is at a different temperature and the load is increased,
the values output by this device could become unstable,
making accurate measurement impossible. In such a
case, wait until the temperature difference ceases to
exist before measuring.
Electrical connection of load cell
o
Connect as shown in the illustration below. Incorrect
connections could result in inability to balance and
in errors occurring in the output voltage when loads
are applied.
Using a cable with bare lead wires
Red
Input (+)
Black
Output (−)
Blue
Input (−)
White
Output (+)
Yellow Shield
o
The shield is not connected to the main body of this
product. For this reason, if grounding is necessary because
of external noise, for example, arrange to ground the
shield to a part other than the body of this unit.
o
Since the cable is directly connected to this unit, use
a specialized cable to increase the length. (Please
consult with us.)
Using a connector (optional)
A Input (+)
B Output (−)
C Input (−)
D Output (+)
E Shield
NDIS-compatible
connector
Handling after use
o
When moving this unit while it is installed, take protective
measures to prevent it from being shaken or subjected
to excessive external forces.
o
When storing it, keep it in a dry place where it will not
be exposed to water or oil, for example.
Specifications
TU-PGRS 100N-G to TU-PGRS 20KN-G
Rated capacity: 100 N, 200 N, 500 N, 1 kN, 2 kN, 3 kN, 5 kN,
10 kN, 20 kN
Safe overload rating: 150% R.C.
Rated output: 2 mV/V ±0.3%
Linearity: 0.03% R.O.
Hysteresis: 0.03% R.O.
Repeatability: 0.02% R.O.
Zero balance: 3% R.O.
Safe excitation voltage: 15 V (100 N, 200 N)
20 V (500 N – 20 kN)
Input terminal resistance: 1050 ±10 Ω
Output terminal resistance: 1050 ±10 Ω
Insulation resistance: 1000 MΩ or higher (DC 50 V)
Compensated temperature range: −10 to 60°C
Permissible temperature range: −30 to 80°C
Temperature effect on zero balance: 0.025% R.O./10°C
Temperature effect on output: 0.03% R.C./10°C
Cable: Ø6mm 4-core shielded, 5m direct connection with
bare lead wires (100 N – 5 kN)
Ø8mm 4-core shielded, 5m direct connection with
bare lead wires (10 kN, 20 kN)
Body material: aluminum (coated surface) (100 N–5 kN)
Steel (coated surface) (10 kN, 20 kN)
Environmental compliance: RoHS (10 substances)
TEDS: not supported
Other: load button included
Dimensional drawings
(dimensions in millimeters (mm))
A
(Ø14)
Ø58
Ø11
Ø44
Ø11
Ø44
26
B
Rubber sleeve
Cable
M8X1.25
Ø51
3x Ø4.5 thr
ough holes
Rated capacity
A
B
100 N
0.15
13
200 N
0.15
13
500 N
0.09 11.5
1 kN
0.09 11.5
TU-PGRS 2K-G to TU-PGRS 5KN-G
(Ø18)
Ø88
Ø62
Ø21
36
18
Rubber sleeve
Cable
M12X1.75
Ø75
6x Ø6.5 thr
ough holes
Ø21
Ø62
0.08
TU-PGRS 10K-G to TU-PGRS 20KN-G
Ø118
Ø79
Ø34
40
20
Rubber sleeve
Cable
M18X1.5
Ø98
6x Ø9 thr
ough holes
0.08
Ø34
Ø79
R1/2 (PT1/2)
Warranty explanation
o
The warranty period for this device is one year from
the date of purchase.
1) Be aware that repairs will require payment in the
following cases even during the warranty period.
Malfunction or damage due to misuse
2) Malfunction or damage caused by modifications or
repairs conducted by any party other than our com-
pany or a service person designated by our company
3) Malfunction or damage caused by dropping, trans-
portation or similar handling after product delivery
4) Malfunction or damage caused by fire, earthquake,
water, lightning or other natural disaster
5) Malfunction or damage caused by external fac-
tors, including power supplies and equipment
environmental conditions, that deviate from the
operation requirements of this product
6) Malfunction or damage if the product was not pur-
chased from our company or an agent designated
by our company
o
We offer paid service after the conclusion of the warranty
period. For details, please contact the retailer where you
purchased the unit.
o
Be aware that our company will bear no responsibility
for any secondary damages resulting from the operation
of this device or related to data.
o
Information is given about products in this manual
only for the purpose of example and does not indicate
any guarantees against infringements of third-party
intellectual property rights and other rights related to
them. TEAC Corporation will bear no responsibility for
infringements on third-party intellectual property rights
or their occurrence because of the use of these products.
Contact information
TEAC CORPORATION (Manufacturer)
1-47 Ochiai, Tama-shi, Tokyo 206-8530 Japan
Phone: +81-042-356-9154
TEAC AMERICA, INC.
10410 Pioneer Blvd. Suite #1, Santa Fe Springs, California 90670,
U.S.A.
Phone: +1-323-726-0303
TEAC EUROPE GmbH. (EU Importer)
Bahnstrasse 12, 65205 Wiesbaden-Erbenheim, Germany
Phone: +49-611-7158-349
0720 MA-2733A
TU-PGRS 100N-G to TU-PGRS 1KN-G