17
3. Setting lists
3-1. Setting value list
Item
Setting
Format
Default value
Setting range/options
FIELD NETWORK
CONTROL INPUT
Selection CONT. TERMINAL
CONT. TERMINAL, COMM.
MEMORY CONTROL
Selection FORBID
FORBID, ALLOW
EtherNet/IP
IP ADDRESS
Input
192.168.0.10
0.0.0.0 to 255.255.255.255
SUBNET MASK
Input
255.255.255.0
0.0.0.0 to 255.255.255.255
DHCP
Selection ENABLE
ENABLE, DISABLE
ATTENTION!
Conducting an operation with the screen, including starting/stopping measurement and switching sensors or work memories, at the
same time that an operation is executed by communication could cause unpredictable malfunction. For this reason, we recommend
prohibiting making changes on screen during communication.
3-2. Serial communication (SERIAL COMM.)
Read the unit operation manual for details about serial communication protocol.
3-2-1. Field network
Content
Command No. Default value
Setting item
Note
Control signal input 5710
0: Control terminal
(CONT. TERMINAL)
0: Control terminal (CONT. TERMINAL),
1: Communication control (COMM.)
Memory control
5711
0: Forbid
0: Forbid, 1: Allow
3-2-2. EtherNet/IP
Content
Command No. Default value
Setting item
Note
DHCP
5720
1: Enabled
0: Disable, 1: Enabled
We recommend turning the power
off and on again after changing this
setting.
IP address
5721
192.168.0.10
000:000:000:000 to
255:255:255:255
Transmit 12 ASCII characters
Subnet mask
5722
255.255.255.0
000:000:000:000 to
255:255:255:255
Transmit 12 ASCII characters
Note
“Field network” and “EtherNet/IP” setting commands will be disabled if the corresponding options are not installed.