DISTRICT
CENTRE (mm)
POSITION
LIMIT (mm)
SCANNING
SIZE (%)
SCANNING
SIZE
LIMIT (%)
THAILAND
FRANCE
GERMANY
*GROUP A
*GROUP B
*GROUP C
-1
+3
+3
-2
0
+3
0 ~ -2
0 ~ +5
0 ~ +5
-5 ~ -1
-2 ~ +2
0 ~ +5
90
90
90
90
90
90
88 ~ 92
88 ~ 94
90 ~ 95
88 ~ 94
88 ~ 94
88 ~ 94
mm -5 -4 -3 -2 -1 0 1 2 3 4 5 mm
LEFT
RIGHT
CENTRE OF
THE SCREEN
CRT MUST
FACE TO EAST
REMARK :
1. SUITABLE FOR 14" OR ABOVE TV.
2. Adjust the centre position must take the upper side of monoscope
pattern for standard.
3. Group A : AUSTRALIA, NEW ZEALAND, TAHITI.
4. Group B : HONG KONG, CHINA, AMERICA, CANADA, MALAYSIA,
MEXICO.
5. Group C : ENGLAND, ITALY, GERMANY, RUSSIA, SWITZERLAND,
JUGOSLAVIA, SPANISH.
If the above countries are not include, please consult to
Engineering Dept.